{
  "abstract": "The purpose of this study was to compare the spectral performance of three dual-energy CT (DECT) scanners and one photon-counting CT (PCCT) scanner on virtual monoenergetic images (VMIs) at low-energy levels and on iodine maps.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": null,
  "author_total": 8,
  "authors": [
    {
      "name": "Joël Greffier"
    },
    {
      "name": "Cécile Salvat"
    },
    {
      "name": "Maxime Pastor"
    },
    {
      "name": "Valérie Bousson"
    },
    {
      "name": "Salim Si-Mohamed"
    },
    {
      "name": "Jean-Paul Beregi"
    },
    {
      "name": "Lama Hadid-Beurrier"
    },
    {
      "name": "Djamel Dabli"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/157r98ndsjbmw.bib",
  "cited_by": 11,
  "doi": "10.1016/j.diii.2025.11.007",
  "fulltext_url": null,
  "id": "157r98ndsjbmw",
  "issns": [
    "2211-5684",
    "2211-5684"
  ],
  "landing_url": "https://hal.science/hal-05788210v1",
  "language": "en",
  "licence": "CC-BY-SA-4.0",
  "licence_label": "CC BY-SA 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-sa/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "hal",
      "0.phys"
    ],
    [
      "openalex",
      "2204|Advanced X-ray and CT Imaging"
    ]
  ],
  "openalex": "W4416808443",
  "pdf_url": "https://hal.science/hal-05788210/document",
  "pmcid": null,
  "pmid": "41318304",
  "published": "2026-10-09",
  "publisher": "Elsevier",
  "ris": "https://research.draconitic.com/paper/157r98ndsjbmw.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:17:52Z",
      "native_id": "hal-05788210",
      "source": "hal",
      "url": "https://hal.science/hal-05788210v1"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "hal:0.phys",
      "subfield": "general"
    }
  ],
  "title": "Comparison of spectral performance of three dual-energy CT scanners equipped with a deep-learning image reconstruction algorithm and one photon counting CT scanner: A phantom study",
  "title_text": "Comparison of spectral performance of three dual-energy CT scanners equipped with a deep-learning image reconstruction algorithm and one photon counting CT scanner: A phantom study",
  "type": "peer-reviewed",
  "updated_at": "2026-10-30T12:17:52Z",
  "url": "https://research.draconitic.com/paper/157r98ndsjbmw",
  "venue": "Diagnostic and Interventional Imaging",
  "versions": []
}