  "abstract": "High-purity germanium (HPGe) detectors with low capacitance, low electronic noise, and stable high-voltage operation are important for high-resolution gamma-ray spectroscopy and rare-event searches. We report the fabrication and characterization of two compact p-type inverted coaxial point-contact (ICPC) HPGe detectors, AK01 and AK02, produced from crystals grown at the University of South Dakota. Both devices use lithium-diffused $n^{+}$ outer contacts together with amorphous-Ge/Al point-contact electrodes. The principal advance is the implementation of this hybrid contact process on two independently fabricated USD-grown ICPC prototypes and the demonstration of stable electrical and spectroscopic operation. Both detectors exhibited picoampere-level leakage currents, operational depletion-voltage ranges of approximately 200--250~V (AK01) and 240--260~V (AK02), and estimated effective plateau capacitances of approximately 0.84 and 0.87~pF, respectively. Measurements with a $^{137}$Cs source yielded archived full-energy-peak FWHM values of 1.71 and 1.62~keV near 662~keV for AK01 and AK02, while AK02 yielded 1.04~keV FWHM at 59.5~keV with $^{241}$Am. Electric-field calculations reproduce the expected ICPC field configuration for the measured detector geometry. A Geant4 model of AK02 is used as a qualitative response study; its 0.8-mm Li-diffused inactive layer is an illustrative model assumption rather than a measured thickness, and its Gaussian broadening is constrained by the experimental resolution. The work therefore establishes the fabrication and operation of compact lithium-diffused ICPC prototypes while identifying quantitative inactive-layer characterization as an important next step.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": "2609.01522",
  "author_total": 3,
  "authors": [
    {
      "name": "Anupama Karki"
    },
    {
      "name": "Kunming Dong"
    },
    {
      "name": "Dongming Mei"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/1w9w9nxxp2y94.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2609.01522",
  "fulltext_url": null,
  "id": "1w9w9nxxp2y94",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2609.01522",
  "language": null,
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "http://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "physics.ins-det"
    ],
    [
      "openalex",
      "3108|Radiation Detection and Scintillator Technologies"
    ]
  ],
  "openalex": "W7206173259",
  "pdf_url": "https://arxiv.org/pdf/2609.01522",
  "pmcid": null,
  "pmid": null,
  "published": "2026-09-01",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/1w9w9nxxp2y94.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:18:00Z",
      "native_id": "2609.01522",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2609.01522"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "arxiv:physics.ins-det",
      "subfield": "applied-instrumentation"
    }
  ],
  "title": "Fabrication and characterization of lithium-diffused inverted coaxial point-contact HPGe detectors",
  "title_text": "Fabrication and characterization of lithium-diffused inverted coaxial point-contact HPGe detectors",
  "type": "preprint",
  "updated_at": "2026-10-30T12:18:00Z",
  "url": "https://research.draconitic.com/paper/1w9w9nxxp2y94",
  "venue": "arXiv",
  "versions": []
}