  "abstract": "Objectives: The aim of this study was to compare the effects of balloon-expandable and self-expanding stents on vessel wall mechanics and hemodynamics in a patient-specific saccular abdominal aortic aneurysm model.\n\nMethods: A patient-specific aneurysm model was constructed using computed tomography images, and balloon-expandable and self-expanding stent models were created. Aortic wall stress was evaluated by contact analysis. Fluid–structure interaction analyses were performed at 5 representative phases selected from the cardiac cycle. Mean intra-aneurysmal flow velocity, wall shear stress (WSS), pressure loss, and energy loss were compared.\n\nResults: The balloon-expandable stent produced greater localized aortic wall stress than the self-expanding stent, whereas wall stress was more uniformly distributed with the self-expanding stent. Both stents reduced the mean intra-aneurysmal flow velocity, WSS, pressure loss, and energy loss compared with the no-stent model. However, greater reductions in WSS, pressure loss, and energy loss were noted with the balloon-expandable stent than with the self-expanding stent.\n\nConclusions: Balloon-expandable and self-expanding stents exhibited different effects on vessel wall mechanics and hemodynamics. The findings indicate the importance of evaluating both hemodynamic and mechanical effects when assessing stent–vessel interactions.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Cardiovascular Surgery, National Hospital Organization Kanmon Medical Center, Shimonoseki, Yamaguchi, Japan",
    "Department of Mechanical Engineering, Graduate School of Sciences and Technology for Innovation, Yamaguchi University, Ube, Yamaguchi, Japan"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 4,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Masanori Murakami"
    },
    {
      "affs": [
        1
      ],
      "name": "Fei Jiang"
    },
    {
      "affs": [
        1
      ],
      "name": "Tatsuo Yamashita"
    },
    {
      "affs": [
        1
      ],
      "name": "Shinsuke Mochizuki"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/1wy8jdvpp0h85.bib",
  "cited_by": 0,
  "doi": "10.3400/avd.oa.26-00052",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13710210/",
  "id": "1wy8jdvpp0h85",
  "issns": [
    "1881-641X",
    "1881-6428"
  ],
  "landing_url": "https://doi.org/10.3400/avd.oa.26-00052",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Original Article"
    ],
    [
      "openalex",
      "2740|Aortic aneurysm repair treatments"
    ]
  ],
  "openalex": "W7223249617",
  "pdf_url": "https://www.jstage.jst.go.jp/article/avd/19/1/19_oa.26-00052/_pdf",
  "pmcid": "PMC13710210",
  "pmid": "42947723",
  "published": "2026-10-23",
  "publisher": "Editorial Committee of Annals of Vascular Diseases",
  "ris": "https://research.draconitic.com/paper/1wy8jdvpp0h85.ris",
  "sources": [
    {
      "first_seen": "2026-10-31T12:21:13Z",
      "native_id": "PMC13710210",
      "source": "pmc",
      "url": "https://doi.org/10.3400/avd.oa.26-00052"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2740|Aortic aneurysm repair treatments",
      "subfield": "general"
    }
  ],
  "title": "Mechanical and Hemodynamic Effects of Balloon-Expandable and Self-Expanding Stents in a Saccular Abdominal Aortic Aneurysm Model: Fluid–Structure Interaction Analyses",
  "title_text": "Mechanical and Hemodynamic Effects of Balloon-Expandable and Self-Expanding Stents in a Saccular Abdominal Aortic Aneurysm Model: Fluid–Structure Interaction Analyses",
  "type": "peer-reviewed",
  "updated_at": "2026-10-31T12:21:13Z",
  "url": "https://research.draconitic.com/paper/1wy8jdvpp0h85",
  "venue": "Annals of Vascular Diseases",
  "versions": []
}