{
  "abstract": "Background/Objectives: Centerline Dice (clDice) emphasizes skeleton overlap, but a high score does not establish connectivity. This empirical study, which proposes no new metric, measured how often high-scoring pancreatic-duct segmentations on computed tomography (CT) differ from their references in connected-component count, and what changes that frequency. Methods: Dice, clDice and component counts were compared for 235 held-out PANORAMA CT predictions of a public model. The references were algorithm-generated, so a difference shows disagreement, not anatomical correctness. Thresholds, small-component cleanup and skeleton-based counting were varied. Further tests used a second model, known cuts, synthetic tubes and retinal labels. Synthetic-tube radii illustrate the mechanism, not clinical thresholds. Results: Among 81 predictions with both scores above 0.85, 51 (63.0%; 95% CI 52-73%) differed in component count; a second model gave 32 of 55 (58.2%). Among 86 predictions with Dice above 0.85, cleanup alone moved discordant cases between 25 and 60, and skeleton-based counting reclassified seven cases. After one known cut, 194 of 199 references kept both scores above 0.85 despite the break. Conclusions: High clDice does not ensure matching connectivity. Studies should report a direct connectivity measure alongside clDice and state their cleanup and skeletonization conventions, because these conventions alone changed the reported frequency.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Engineering Sciences, Jade Hochschule Wilhelmshaven, 26389 Wilhelmshaven, Germany."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 3,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Souraj Adhikary",
      "orcid": "0009-0005-4847-0348"
    },
    {
      "affs": [
        0
      ],
      "name": "Negar Chabi",
      "orcid": "0000-0002-9530-8133"
    },
    {
      "affs": [
        0
      ],
      "name": "Andre Mastmeyer",
      "orcid": "0000-0003-0561-8363"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/26k36h14wf8zz.bib",
  "cited_by": 0,
  "doi": "10.3390/tomography12110155",
  "fulltext_url": "https://europepmc.org/articles/PMC13808510",
  "id": "26k36h14wf8zz",
  "issns": [
    "2379-1381",
    "2379-139X"
  ],
  "landing_url": "https://europepmc.org/article/MED/43083645",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "1707|Medical Image Segmentation Techniques"
    ]
  ],
  "openalex": "W7204096362",
  "pdf_url": "https://europepmc.org/articles/PMC13808510?pdf=render",
  "pmcid": "PMC13808510",
  "pmid": "43083645",
  "published": "2026-10-27",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/26k36h14wf8zz.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T15:23:43Z",
      "native_id": "MED:43083645",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43083645"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "journal-openalex:2741|Advanced MRI Techniques and Applications",
      "subfield": "imaging"
    }
  ],
  "title": "Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.",
  "title_text": "Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:23:43Z",
  "url": "https://research.draconitic.com/paper/26k36h14wf8zz",
  "venue": "Tomography (Ann Arbor, Mich.)",
  "versions": []
}