  "abstract": null,
  "abstract_shown": false,
  "affiliations": [
    "Department of Electrophysiology, Heart Center, Medical Faculty and University Hospital Cologne, University of Cologne, Cologne, Germany.",
    "Department of Gynecology and Gynecologic Oncology, Medical Faculty and University Hospital Cologne, University of Cologne, Cologne, Germany."
  ],
  "article_type": null,
  "arxiv": null,
  "author_total": 5,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Theodoros Maximidou"
    },
    {
      "affs": [
        1
      ],
      "name": "Jonas Wörmann"
    },
    {
      "affs": [
        1
      ],
      "name": "Wolfram Malter"
    },
    {
      "affs": [
        0
      ],
      "name": "Daniel Steven"
    },
    {
      "affs": [
        0
      ],
      "name": "Jakob Lüker"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/28bnf2jq4yfyh.bib",
  "cited_by": 0,
  "doi": "10.1016/j.hrcr.2026.07.018",
  "fulltext_url": "https://europepmc.org/articles/PMC13687959",
  "id": "28bnf2jq4yfyh",
  "issns": [
    "2214-0271"
  ],
  "landing_url": "https://europepmc.org/article/MED/42923774",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2705|Cardiac pacing and defibrillation studies"
    ]
  ],
  "openalex": "W7171811471",
  "pdf_url": "https://europepmc.org/articles/PMC13687959?pdf=render",
  "pmcid": "PMC13687959",
  "pmid": "42923774",
  "published": "2026-07-30",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/28bnf2jq4yfyh.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:21:02Z",
      "native_id": "MED:42923774",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/42923774"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2705|Cardiac pacing and defibrillation studies",
      "subfield": "cardiovascular"
    }
  ],
  "title": "Electrode perforation of a silicone breast implant in a subcutaneous implantable cardioverter-defibrillator carrier: A previously unreported device complication.",
  "title_text": "Electrode perforation of a silicone breast implant in a subcutaneous implantable cardioverter-defibrillator carrier: A previously unreported device complication.",
  "type": "peer-reviewed",
  "updated_at": "2026-10-30T12:21:02Z",
  "url": "https://research.draconitic.com/paper/28bnf2jq4yfyh",
  "venue": "HeartRhythm case reports",
  "versions": []
}