  "abstract": "Thyristor rectifiers (TRs) are cost-effective electrolysis power supplies for renewable power-to-hydrogen (ReP2H) systems, but their harmonics may violate grid-code limits. In contrast to conventional solutions that rely on higher-pulse (such as 24-pulse) rectifiers, this paper proposes an operational harmonic coordination scheme that enables low-cost 12-pulse TRs to meet harmonic requirements through coordinated operation. First, a harmonic model quantifies the effects of rectifier transformer (RCT) tap positions and electrolytic currents, enabling harmonic cancellation among multiple electrolyzers (ELZs). A two-layer framework then coordinates hydrogen production and harmonic mitigation. Hourly scheduling determines ELZ commitment within the harmonic feasible region under renewable uncertainty using stochastic programming and a modified progressive hedging algorithm, while minute-level dispatch tracks renewable power and mitigates harmonics. A decomposition algorithm separates production dispatch from harmonic mitigation to improve computational efficiency. Case studies based on real-life projects show that the proposed method increases profit by 31% over current-only regulation. Annual simulations further show that coordinated 12-pulse TRs can replace 24-pulse rectifiers for harmonic compliance by exchanging additional RCT tap actions for lower transformer investment, reducing rectification-stage cost by 37.5%.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": "2609.03531",
  "author_total": 9,
  "authors": [
    {
      "name": "Yangjun Zeng"
    },
    {
      "name": "Yiwei Qiu"
    },
    {
      "name": "Jie Zhu"
    },
    {
      "name": "Yi Zhou"
    },
    {
      "name": "Tao Wu"
    },
    {
      "name": "Xin Meng"
    },
    {
      "name": "Shi Chen"
    },
    {
      "name": "Buxiang Zhou"
    },
    {
      "name": "Kaigui Xie"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/2hh1t0faw700d.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2609.03531",
  "fulltext_url": null,
  "id": "2hh1t0faw700d",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2609.03531",
  "language": null,
  "licence": "LicenseRef-arXiv-nonexclusive-1.0",
  "licence_label": "arXiv licence",
  "licence_source": "article",
  "licence_url": "http://arxiv.org/licenses/nonexclusive-distrib/1.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "cs.SY"
    ],
    [
      "arxiv",
      "eess.SY"
    ],
    [
      "arxiv",
      "math.OC"
    ],
    [
      "openalex",
      "2102|Hybrid Renewable Energy Systems"
    ]
  ],
  "openalex": "W7208743150",
  "pdf_url": "https://arxiv.org/pdf/2609.03531",
  "pmcid": null,
  "pmid": null,
  "published": "2026-09-03",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/2hh1t0faw700d.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:18:36Z",
      "native_id": "2609.03531",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2609.03531"
    }
  ],
  "subjects": [
    {
      "field": "mathematics",
      "origin": "arxiv:math.OC",
      "subfield": "optimisation-control"
    }
  ],
  "title": "Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems",
  "title_text": "Beyond Higher-Pulse Rectification: Operational Harmonic Coordination in Renewable P2H Systems",
  "type": "preprint",
  "updated_at": "2026-10-30T12:18:36Z",
  "url": "https://research.draconitic.com/paper/2hh1t0faw700d",
  "venue": "arXiv",
  "versions": []
}