{
  "abstract": "This exploratory bench study characterized pressure behavior in a roller pump-driven low-flow valve-type semi-closed extracorporeal circulation (VACC) mock circuit under experimentally reduced patient-side effective filling pressure conditions with the de-airing pump inactive. Pressures were measured at four sites: circuit-reservoir pressure (Pc), patient-side mock-reservoir outlet pressure (Pv), roller pump inlet pressure (Pi), and roller pump outlet pressure (Po). Pump flow-rate settings were 50–300 mL/min. Circuit-reservoir negative-pressure setpoints were 0, −10, −20, −30, and −40 mmHg, and patient-side mock-reservoir negative-pressure setpoints were 0, −5, and −10 mmHg. A 32 wt% aqueous glycerol solution was used. Pc generally reflected the circuit-reservoir negative-pressure setpoint, with a mean difference of −0.18 mmHg (95% CI, −0.37 to 0.00). The 95% CIs summarize variability among technical replicates within this bench system and should not be interpreted as population-inferential estimates. Pv decreased stepwise according to the patient-side setpoint. Within the common evaluation range, mean differences versus 0 mmHg were −5.7 mmHg (95% CI, −6.0 to −5.3) for the −5 mmHg condition and −9.2 mmHg (95% CI, −9.5 to −8.9) for the −10 mmHg condition. Pi shifted in the negative direction as the pump flow-rate setting increased, whereas Po increased monotonically under the fixed occluder condition. Delivered flow was independently verified volumetrically before the main experiments at 100, 200, and 300 mL/min but was not continuously measured during the pressure experiments. Therefore, Po was interpreted primarily in relation to the pump flow-rate setting rather than as a directly measured hydraulic pressure–flow relationship. These data provide baseline pressure-characterization information for future mock-circuit studies and do not establish clinical safety, efficacy, or a stable operating range.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Medical Technology, Faculty of Fukuoka Medical Technology, Teikyo University, Omuta, Fukuoka, Japan",
    "Laboratory of Veterinary Surgery, Joint Faculty of Veterinary Medicine, Yamaguchi University, Yamaguchi, Yamaguchi, Japan",
    "School of Clinical Engineering, Faculty of Health and Medical Care, Saitama Medical University, Hidaka, Saitama, Japan",
    "Department of Clinical Engineering, National Hospital Organization Sendai Medical Center, Sendai, Japan",
    "Department of Clinical Engineering, Saitama Children’s Medical Center, Saitama, Saitama, Japan",
    "Graduate Degree Program of Comprehensive Applied Data Science, Teikyo University, Hachioji, Tokyo, Japan"
  ],
  "article_type": "Research Article",
  "arxiv": null,
  "author_total": 6,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Keizo Wauchi"
    },
    {
      "affs": [
        1
      ],
      "name": "Takahiro Okumura"
    },
    {
      "affs": [
        2
      ],
      "name": "Keisuke Matsuda"
    },
    {
      "affs": [
        3
      ],
      "name": "Hiroki Sato"
    },
    {
      "affs": [
        4
      ],
      "name": "Masahiro Miyata"
    },
    {
      "affs": [
        5
      ],
      "name": "Kenji Tani"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/2sa7t0mtajmd5.bib",
  "cited_by": 0,
  "doi": "10.1371/journal.pone.0363658",
  "fulltext_url": null,
  "id": "2sa7t0mtajmd5",
  "issns": [
    "1932-6203"
  ],
  "landing_url": "https://doi.org/10.1371/journal.pone.0363658",
  "language": null,
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "journal",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2705|Mechanical Circulatory Support Devices"
    ],
    [
      "plos",
      "/Biology and life sciences/Organisms/Eukaryota/Animals/Vertebrates/Amniotes/Mammals/Dogs"
    ],
    [
      "plos",
      "/Biology and life sciences/Physiology/Physiological parameters/Body temperature"
    ],
    [
      "plos",
      "/Biology and life sciences/Zoology/Animals/Vertebrates/Amniotes/Mammals/Dogs"
    ],
    [
      "plos",
      "/Medicine and health sciences/Vascular medicine/Blood pressure"
    ],
    [
      "plos",
      "/Physical sciences/Chemistry/Polymer chemistry/Monomers/Glycerol"
    ],
    [
      "plos",
      "/Physical sciences/Materials science/Materials/Mixtures/Solutions/Aqueous solutions"
    ],
    [
      "plos",
      "/Physical sciences/Physics/Classical mechanics/Continuum mechanics/Fluid mechanics/Fluid dynamics/Bubbles"
    ],
    [
      "plos",
      "/Physical sciences/Physics/Classical mechanics/Continuum mechanics/Fluid mechanics/Fluid dynamics/Fluid flow"
    ],
    [
      "plos",
      "/Physical sciences/Physics/Classical mechanics/Pressure/Hydrostatic pressure"
    ]
  ],
  "openalex": "W7239772298",
  "pdf_url": null,
  "pmcid": null,
  "pmid": null,
  "published": "2026-11-25",
  "publisher": "Public Library of Science",
  "ris": "https://research.draconitic.com/paper/2sa7t0mtajmd5.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T12:20:38Z",
      "native_id": "10.1371/journal.pone.0363658",
      "source": "plos",
      "url": "https://doi.org/10.1371/journal.pone.0363658"
    }
  ],
  "subjects": [
    {
      "field": "chemistry",
      "origin": "plos:polymer chemistry",
      "subfield": "materials-polymers"
    },
    {
      "field": "medicine",
      "origin": "plos:physiology",
      "subfield": "physiology"
    },
    {
      "field": "physics",
      "origin": "plos:fluid dynamics",
      "subfield": "fluid-dynamics"
    }
  ],
  "title": "Pressure behavior in a roller pump-driven low-flow VACC mock circuit with inactive de-airing pump: A descriptive bench characterization under reduced patient-side effective filling pressure conditions",
  "title_text": "Pressure behavior in a roller pump-driven low-flow VACC mock circuit with inactive de-airing pump: A descriptive bench characterization under reduced patient-side effective filling pressure conditions",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T12:20:38Z",
  "url": "https://research.draconitic.com/paper/2sa7t0mtajmd5",
  "venue": "PLOS One",
  "versions": []
}