  "abstract": "Background\n\nMotion artifacts can degrade prostate MRI quality. PROPELLER read-out (PR), a radial acquisition technique, is an established approach that can reduce motion artifacts but requires longer acquisition times. We explored whether combining PR with accelerated acquisition and reconstruction methods yields image quality gains while reducing scan times.Purpose\n\nTo compare the image quality of standard Cartesian (CR) and PROPELLER read-outs (PR) using an accelerated fast spin echo-based technique (VORTEX), combined with deep learning reconstruction (DLR).Materials and methods\n\nIn 80 consecutive patients, VORTEX with CR was performed for the axial, sagittal, and coronal planes with scan time of 84, 50, and 54 s, respectively, while VORTEX with PR was performed in the coronal (71 s) and sagittal planes (92 s), for a total of five imaging datasets. All datasets were reconstructed using a commercially available DLR (AIRTM Recon DL). Five radiologists performed image quality assessments. Inter-reader agreement was estimated using Gwet's AC2 statistics.Results\n\nAll VORTEX derived images were assigned a T₂w image PI-QUAL score of ≥3, and all radiologists perceived fewer artifacts in the sagittal and coronal PROPELLER images (p < .001). Four out of five radiologists also observed both superior overall image quality and reduced noise for all PROPELLER derived images (p < .001). Inter-rater agreement was good to very good for all assessments (AC2 0.77-0.88).Conclusion\n\nVORTEX with PR and DLR can achieve fast high-quality T₂w sagittal and coronal imaging of prostate, with all acquisitions completed within 95 s per imaging plane and a total triplanar acquisition time of 4 min 7 s.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Radiology, Massachusetts General Hospital, Mass General Brigham, Boston, MA, USA.",
    "Harvard Medical School, Boston, MA, USA.",
    "GE HealthCare, Boston, MA, USA.",
    "GE HealthCare, Waukesha, WI, USA.",
    "GE HealthCare, Rochester, MN, USA.",
    "Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA.",
    "Department of Radiology, Brigham and Women's Hospital, Mass General Brigham, Boston, MA, USA.",
    "Enterprise Service Group - Radiology, Mass General Brigham, Boston, MA, USA.",
    "Department of Radiology, University of Turku, Turku, Finland."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 15,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Rory L Cochran",
      "orcid": "0000-0001-9123-4010"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Ranjodh S Dhami"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "William R Bradley"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Robert G Rasmussen"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Madhangi Parameswaran"
    },
    {
      "affs": [
        2
      ],
      "name": "Eugene Milshteyn"
    },
    {
      "affs": [
        3
      ],
      "name": "Ajeetkumar Gaddipati"
    },
    {
      "affs": [
        2
      ],
      "name": "Mary Thomas"
    },
    {
      "affs": [
        3
      ],
      "name": "Anand Venkatachari"
    },
    {
      "affs": [
        4
      ],
      "name": "Arnaud Guidon",
      "orcid": "0000-0001-6777-1633"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Azadeh Tabari",
      "orcid": "0000-0002-5685-6401"
    },
    {
      "affs": [
        0,
        1,
        5
      ],
      "name": "Susie Y Huang"
    },
    {
      "affs": [
        1,
        6
      ],
      "name": "Clare M Tempany"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Mukesh G Harisinghani"
    },
    {
      "affs": [
        1,
        7,
        8
      ],
      "name": "Ivan Jambor",
      "orcid": "0000-0001-6305-3570"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/2t6a3e2cw5qq0.bib",
  "cited_by": 0,
  "doi": "10.1177/20584601261492967",
  "fulltext_url": "https://europepmc.org/articles/PMC13775190",
  "id": "2t6a3e2cw5qq0",
  "issns": [
    "2058-4601"
  ],
  "landing_url": "https://europepmc.org/article/MED/43048090",
  "language": "eng",
  "licence": "CC-BY-NC",
  "licence_label": "CC BY-NC",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Original Article"
    ],
    [
      "openalex",
      "2741|Advanced MRI Techniques and Applications"
    ]
  ],
  "openalex": "W7221349728",
  "pdf_url": "https://europepmc.org/articles/PMC13775190?pdf=render",
  "pmcid": "PMC13775190",
  "pmid": "43048090",
  "published": "2026-10-10",
  "publisher": "SAGE Publications",
  "ris": "https://research.draconitic.com/paper/2t6a3e2cw5qq0.ris",
  "sources": [
    {
      "first_seen": "2026-11-20T15:21:58Z",
      "native_id": "MED:43048090",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43048090"
    },
    {
      "first_seen": "2026-11-21T12:22:08Z",
      "native_id": "PMC13775190",
      "source": "pmc",
      "url": "https://doi.org/10.1177/20584601261492967"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2741|Advanced MRI Techniques and Applications",
      "subfield": "imaging"
    }
  ],
  "title": "Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.",
  "title_text": "Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-21T12:22:08Z",
  "url": "https://research.draconitic.com/paper/2t6a3e2cw5qq0",
  "venue": "Acta radiologica open",
  "versions": []
}