{
  "abstract": "BackgroundQuantitative computed tomography (CT) and radiomics may support differential diagnosis of established immune checkpoint inhibitor-related pneumonitis (CIP), but transportable accuracy and clinical utility remain uncertain.MethodsSix databases were searched in June 2026, with a documented public-index update through 31 August 2026. Current etiologic attribution was distinguished from future-risk prediction. Revision-stage author assessments and final adjudication were supplemented by a complete 3,900-record disposition log. Abstracts and preprints were included as a distinct evidence stratum; the accuracy synthesis used full-length published reports. Risk of bias was reassessed using tailored Quality Assessment of Diagnostic Accuracy Studies, version 3 (QUADAS-3) at the accuracy-estimate level, with separate descriptive-study appraisal.ResultsThe review includes 17 reports: 13 full-length publications (11 accuracy reports and two descriptive comparisons), three abstracts and one indexed preprint. One included abstract is a companion, without duplicate cohort counting. Twenty-one areas under the receiver operating-characteristic curve (AUCs) and 10 sensitivity/specificity pairs were appraised; 20 estimates had high risk and 11 had insufficient information. These estimates were not independent cohorts. Validation was predominantly internal; one report included mixed-institution rather than purely external validation. The only compatible patient-level CIP-versus-radiation-pneumonitis hold-out operating point involved 40 patients: sensitivity 0.75 (exact 95% CI 0.51–0.91) and specificity 0.60 (0.36–0.81). No meta-analysis was performed. Prospective artificial intelligence (AI)-assisted reader or management-benefit evaluation was not identified among included reports.ConclusionsThe evidence supports within-dataset discrimination, not established transportable diagnostic utility. Unavailable full texts, historical validation limitations and incomplete cross-source linkage constrain evidence completeness. Independent attribution, locked patient-level testing, genuinely external validation and prospective clinical-impact evaluation remain priorities.",
  "abstract_shown": true,
  "affiliations": [
    "School of Biomedical Engineering, Tsinghua University, Beijing, China",
    "Medical Department, Yidu Cloud (Beijing) Technology Co., Ltd., Beijing, China",
    "Department of Critical Care Medicine, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China"
  ],
  "article_type": "Systematic Review",
  "arxiv": null,
  "author_total": 3,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Nan Huang"
    },
    {
      "affs": [
        1
      ],
      "name": "Yifan Jia"
    },
    {
      "affs": [
        2
      ],
      "name": "Yanli Yang"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/34ms8zbb2bf1c.bib",
  "cited_by": 0,
  "doi": "10.3389/fonc.2026.1949897",
  "fulltext_url": "https://www.frontiersin.org/articles/10.3389/fonc.2026.1949897/full",
  "id": "34ms8zbb2bf1c",
  "issns": [
    "2234-943X"
  ],
  "landing_url": "https://doi.org/10.3389/fonc.2026.1949897",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "feed-journal",
      "medicine/oncology"
    ],
    [
      "lcc",
      "RC254-282"
    ]
  ],
  "openalex": null,
  "pdf_url": null,
  "pmcid": null,
  "pmid": null,
  "published": "2026-11-18",
  "publisher": "Frontiers Media S.A.",
  "ris": "https://research.draconitic.com/paper/34ms8zbb2bf1c.ris",
  "sources": [
    {
      "first_seen": "2026-11-18T15:22:12Z",
      "native_id": "0af2882e992a4f1eb8d2058148cab70b",
      "source": "doaj",
      "url": "https://doi.org/10.3389/fonc.2026.1949897"
    },
    {
      "first_seen": "2026-11-18T18:21:08Z",
      "native_id": "10.3389/fonc.2026.1949897",
      "source": "feed-frontiers",
      "url": "https://www.frontiersin.org/articles/10.3389/fonc.2026.1949897"
    },
    {
      "first_seen": "2026-11-19T00:21:28Z",
      "native_id": "10.3389/fonc.2026.1949897",
      "source": "crossref",
      "url": "https://www.frontiersin.org/articles/10.3389/fonc.2026.1949897/full"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "feed-journal:medicine/oncology",
      "subfield": "oncology"
    }
  ],
  "title": "Quantitative computed tomography and radiomics as imaging biomarkers for immune checkpoint inhibitor-related pneumonitis: a systematic review of differential diagnosis",
  "title_text": "Quantitative computed tomography and radiomics as imaging biomarkers for immune checkpoint inhibitor-related pneumonitis: a systematic review of differential diagnosis",
  "type": "peer-reviewed",
  "updated_at": "2026-11-20T18:20:18Z",
  "url": "https://research.draconitic.com/paper/34ms8zbb2bf1c",
  "venue": "Frontiers in Oncology",
  "versions": []
}