  "abstract": "Background\n\nSevere thoracic deformity in ankylosing spondylitis (AS) can complicate implantable cardioverter defibrillator (ICD) implantation and device selection. Substernal EV-ICD implantation requires careful anatomical assessment and individualized procedural planning.Case summary\n\nA 57-year-old male with severe AS and dilated cardiomyopathy was referred for primary prevention ICD implantation. Given the high complication risks associated with conventional approaches, EV-ICD was selected. A tailored positioning strategy was employed to accommodate the thoracic deformity. Intraoperative resistance during substernal dissection was successfully overcome through meticulous re-dissection. Favourable intraoperative electrical parameters were obtained, including an R-wave sensing amplitude of 5.6 mV without P-wave oversensing and successful defibrillation at 30 J on the first attempt. At 6-month follow-up, device performance remained stable without sensing anomalies or inappropriate shocks.Discussion\n\nThis case demonstrates the technical feasibility of EV-ICD implantation in a carefully selected patient with severe AS-associated thoracic deformity. Preoperative CT assessment, tailored patient positioning, careful dissection, and surgical backup enabled successful implantation and stable device performance during 6 months of follow-up.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Cardiology, the Second Xiangya Hospital of Central South University, middle Ren-Min road No.139, Changsha, Hunan 410011, PR China.",
    "Medtronic(Shanghai) Management Co., Ltd."
  ],
  "article_type": null,
  "arxiv": null,
  "author_total": 5,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Jia He",
      "orcid": "0000-0003-1501-1370"
    },
    {
      "affs": [
        0
      ],
      "name": "Qiming Liu",
      "orcid": "0000-0002-5213-2668"
    },
    {
      "affs": [
        1
      ],
      "name": "Zean Zhu",
      "orcid": "0009-0001-0890-0754"
    },
    {
      "affs": [
        0
      ],
      "name": "Zhenjiang Liu"
    },
    {
      "affs": [
        0
      ],
      "name": "Zhihong Wu",
      "orcid": "0000-0001-9575-2894"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/3jzdr9ynyeezq.bib",
  "cited_by": 0,
  "doi": "10.1093/ehjcr/ytag758",
  "fulltext_url": "https://europepmc.org/articles/PMC13690091",
  "id": "3jzdr9ynyeezq",
  "issns": [
    "2514-2119"
  ],
  "landing_url": "https://europepmc.org/article/MED/42924249",
  "language": "eng",
  "licence": "CC-BY-NC",
  "licence_label": "CC BY-NC",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2705|Cardiac pacing and defibrillation studies"
    ]
  ],
  "openalex": "W7222223659",
  "pdf_url": "https://europepmc.org/articles/PMC13690091?pdf=render",
  "pmcid": "PMC13690091",
  "pmid": "42924249",
  "published": "2026-10-15",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/3jzdr9ynyeezq.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:20:33Z",
      "native_id": "MED:42924249",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/42924249"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2705|Cardiac pacing and defibrillation studies",
      "subfield": "cardiovascular"
    }
  ],
  "title": "Successful extravascular implantable cardioverter defibrillator implantation in a patient with ankylosing spondylitis and severe thoracic deformity: a case report.",
  "title_text": "Successful extravascular implantable cardioverter defibrillator implantation in a patient with ankylosing spondylitis and severe thoracic deformity: a case report.",
  "type": "peer-reviewed",
  "updated_at": "2026-10-30T12:20:33Z",
  "url": "https://research.draconitic.com/paper/3jzdr9ynyeezq",
  "venue": "European heart journal. Case reports",
  "versions": []
}