  "abstract": "Mould-based replication, such as injection moulding with 3D-printed inserts, needs a check of how faithfully microchannels are transferred from master to polymer replica. It is usually limited to a width or depth ratio from one cross-section, which misses the sidewall shape and depends on where the section is taken. We present a workflow that assesses the whole channel from 3D scans of master and replica, without sectioning. The scans are registered on a common grid, and each height map is converted into a map of local slope. The correlation of the two slope maps over the channel interior, RQ$_d$, is reported with the channel dimensions and height- and slope-error maps. These outputs separate a change of shape from a change of size and locate it. A user can thereby compare mould materials, detect tool wear, and tell whether a deviation arose before or during moulding. On synthetic channels with known degradation, RQ$_d$ fell steadily as the sidewalls were rounded, whereas the height correlation levelled off. For injection moulding with stereolithography-printed inserts in three resins, RQ$_d$ ranged from 0.17 to 0.91 over fifteen insert-to-part pairs. The height correlation placed the ten well-formed channels within 0.03. Over a twenty-shot run, one insert's RQ$_d$ fell from 0.90 to 0.72 as its sidewalls wore, while its height correlation stayed above 0.93. We developed open-source software that implements the workflow. Because the workflow needs only registered 3D scans of a master and its replica, it can in principle be applied to other mould-based processes.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": "2610.39046",
  "author_total": 3,
  "authors": [
    {
      "name": "Mehmet Oğulcan Güngör"
    },
    {
      "name": "Jérôme Charmet"
    },
    {
      "name": "Ender Yıldırım"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/3r0ebrw2qfs39.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2610.39046",
  "fulltext_url": null,
  "id": "3r0ebrw2qfs39",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2610.39046",
  "language": null,
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "http://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "physics.app-ph"
    ],
    [
      "arxiv",
      "physics.data-an"
    ]
  ],
  "openalex": null,
  "pdf_url": "https://arxiv.org/pdf/2610.39046",
  "pmcid": null,
  "pmid": null,
  "published": "2026-10-28",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/3r0ebrw2qfs39.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:36:23Z",
      "native_id": "2610.39046",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2610.39046"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "arxiv:physics.app-ph",
      "subfield": "applied-instrumentation"
    },
    {
      "field": "physics",
      "origin": "arxiv:physics.data-an",
      "subfield": "computational"
    }
  ],
  "title": "A 3D measurement workflow for assessing replication quality and tool degradation in moulded microfluidic channels",
  "title_text": "A 3D measurement workflow for assessing replication quality and tool degradation in moulded microfluidic channels",
  "type": "preprint",
  "updated_at": "2026-11-01T12:20:45Z",
  "url": "https://research.draconitic.com/paper/3r0ebrw2qfs39",
  "venue": "arXiv",
  "versions": []
}