{
  "abstract": "The degree of polarisation correlation of the two annihilation photons, measured by Compton polarimetry, has been proposed as a PET biomarker of tissue microstructure, but the statistics it requires have not been quantified. We parameterise the measurement by the linear-polarisation correlation coefficient $κ$ ($κ=1$ maximally entangled, $1/2$ separable), derive the classical Fisher information of double-Compton events and compare it with the quantum Fisher information, relate $κ$ to the annihilation channels of positronium in tissue, and simulate pixelated CdZnTe (CZT) rings. The model is checked against three published measurements and an independent GATE/Geant4 simulation. A double-Compton event carries at most 0.12-0.14 units of Fisher information about $κ$ and 0.015 on average, 0.1-0.6% of the quantum limit. Event-wise maximum likelihood reaches the Cramer-Rao bound, whereas the conventional ratio R needs 1.2-2.3 times more events. The observed coefficient is $κ_{obs}=1-α(1-κ_{pick})$, with a pick-off share $α$ of 0.13-0.29 in tissue; it is sensitive to lipid fraction but not to oxygen, and carries no tissue information if pick-off photons are maximally entangled. Published porous-polymer data imply $κ_{pick}$ = 0.34-0.58. In a 15-mm CZT module, ordering ambiguity, position errors and electron transport roughly halve the information per event, and sequence reconstruction of multi-site events recovers this loss. With $^{18}$F and an eight-module ring, $κ$ can be measured to $\\pm0.01$ in a 10-mm tumour, but separating tissues by $κ$ alone requires 6-74 times more decays than are available.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": "2611.21022",
  "author_total": 5,
  "authors": [
    {
      "name": "Haitao Zhou"
    },
    {
      "name": "Ruonan Wang"
    },
    {
      "name": "Jianyong Hu"
    },
    {
      "name": "Zhifang Wu"
    },
    {
      "name": "Sijin Li"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/444bht06akn2b.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2611.21022",
  "fulltext_url": null,
  "id": "444bht06akn2b",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2611.21022",
  "language": null,
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "http://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "quant-ph"
    ]
  ],
  "openalex": null,
  "pdf_url": "https://arxiv.org/pdf/2611.21022",
  "pmcid": null,
  "pmid": null,
  "published": "2026-11-16",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/444bht06akn2b.ris",
  "sources": [
    {
      "first_seen": "2026-11-17T06:20:40Z",
      "native_id": "2611.21022",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2611.21022"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "arxiv:quant-ph",
      "subfield": "quantum"
    }
  ],
  "title": "How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors",
  "title_text": "How many events does entanglement-based positronium imaging need? Information limits of Compton polarimetry with CZT detectors",
  "type": "preprint",
  "updated_at": "2026-11-26T10:21:44Z",
  "url": "https://research.draconitic.com/paper/444bht06akn2b",
  "venue": "arXiv",
  "versions": []
}