{
  "abstract": "Indoor particulate matter is a Group 1 carcinogen with no identified exposure threshold, and the portable air cleaners now widely deployed in European schools, hospitals and offices are almost always evaluated by a change in mean concentration measured before and after installation in the same room. We applied a probabilistic incremental lifetime cancer risk (ILCR) framework to size-resolved particulate matter in thirteen occupied micro-environments in five countries, monitored continuously at five-minute resolution within the TwinAIR pilot network, and then tested that evaluation design against the measurements it rests on. Risk was uniformly low: every site-by-fraction estimate fell below the 10⁻⁶ de minimis threshold by between one and three orders of magnitude, and the conclusion survived recomputation from the measured concentration distributions (11.2 to 353 times below the threshold across forty-two estimates) and the substitution of paediatric exposure parameters. The evaluation design did not survive. In the two rooms that received air cleaners, measured PM2.5 rose by 7.8% and 21.0%, while a thermo-hygrometric regression explaining 1-6% of the variance-the concentration model underlying the probabilistic estimates-predicted reductions of 6.7% and 2.3%. Applying the same phase boundary to four sensors in three micro-environments that received no device produced changes from -74.3% to +37.2%, exceeding in magnitude and spanning in direction the contrast attributed to the intervention. The novelty of this work is therefore twofold: a harmonised probabilistic risk assessment of thirteen real occupied interiors on a single scale, and a demonstration, from the same network's data, that within-room pre-post designs without concurrent controls cannot identify an air-cleaning effect.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Medicine, University of Patras, 26504 Patras, Greece.",
    "Department of Civil Engineering, University of Patras, 26504 Patras, Greece."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 7,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Ioanna P Chatziprodromidou",
      "orcid": "0000-0001-6242-1351"
    },
    {
      "affs": [
        0
      ],
      "name": "Rafail Fokas",
      "orcid": "0009-0006-8957-8029"
    },
    {
      "affs": [
        0
      ],
      "name": "Angeliki Chatziantoniou",
      "orcid": "0009-0007-3582-1705"
    },
    {
      "affs": [
        0
      ],
      "name": "Kalypso Angeliki Koukouvini",
      "orcid": "0000-0001-8708-0960"
    },
    {
      "affs": [
        1
      ],
      "name": "Stylianos Karatzas",
      "orcid": "0000-0001-8318-6100"
    },
    {
      "affs": [
        0
      ],
      "name": "Apostolos Vantarakis",
      "orcid": "0000-0003-4411-3739"
    },
    {
      "name": "TwinAIR Consortium"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/47scye82gc91v.bib",
  "cited_by": 0,
  "doi": "10.3390/toxics14110937",
  "fulltext_url": "https://europepmc.org/articles/PMC13808549",
  "id": "47scye82gc91v",
  "issns": [
    "2305-6304"
  ],
  "landing_url": "https://europepmc.org/article/MED/43083547",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2307|Indoor Air Quality and Microbial Exposure"
    ]
  ],
  "openalex": "W7223978603",
  "pdf_url": "https://europepmc.org/articles/PMC13808549?pdf=render",
  "pmcid": "PMC13808549",
  "pmid": "43083547",
  "published": "2026-10-23",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/47scye82gc91v.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T15:23:43Z",
      "native_id": "MED:43083547",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43083547"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2307|Indoor Air Quality and Microbial Exposure",
      "subfield": "pharmacology-toxicology"
    }
  ],
  "title": "Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).",
  "title_text": "Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:23:43Z",
  "url": "https://research.draconitic.com/paper/47scye82gc91v",
  "venue": "Toxics",
  "versions": []
}