  "abstract": "Subject-specific gait inputs are often unavailable for knee finite element studies, where literature-based cohort-averaged, i.e., generalized, gait inputs are commonly used instead. However, the extent to which this choice affects predicted meniscal mechanics is unclear. We compared the effects of subject-specific and generalized gait inputs on meniscal mechanics using a coupled musculoskeletal-finite element framework with MRI-based knee models from three female participants. Subject-specific gait inputs were derived from motion capture and musculoskeletal modeling, whereas generalized gait inputs were taken from the literature. Both input types were applied to the same participant-specific finite element models, with unchanged geometry and material properties, to estimate bias in medial and lateral meniscal stresses, logarithmic strains, and fluid pressures during the walking stance. Compared with the subject-specific inputs, the generalized gait inputs increased predicted medial meniscus internal stresses and strains, as well as cartilage-meniscus contact surface maximum principal stress by ~50%-250% during the loading response, whereas corresponding lateral meniscus responses were reduced by ~50%. These findings indicate that generalized gait inputs can introduce compartment-specific bias in tissue-level meniscal mechanical predictions, even when subject-specific knee geometry and same material properties are used. Subject-specific gait inputs may therefore be an important feature for assessing tissue failure risk, degeneration progression, or treatment and rehabilitation effects.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Technical Physics, University of Eastern Finland, Kuopio, Finland.",
    "Department of Biomedical Engineering, Lund University, Lund, Sweden.",
    "Imaging Center, Kuopio University Hospital, Wellbeing Services County of North Savo, Kuopio, Finland.",
    "The Parker Institute, Copenhagen University Hospital Bispebjerg-Frederiksberg, Copenhagen, Denmark.",
    "Department of Biomedical Sciences, University of Copenhagen, Copenhagen, Denmark.",
    "Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Queensland, Gold Coast, Australia.",
    "Clinical Research Center, Kuopio University Hospital, Wellbeing Services County of North Savo, Kuopio, Finland.",
    "Department of Oncology, Kuopio University Hospital, Wellbeing Services County of North Savo, Kuopio, Finland."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 11,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Sana Jahangir",
      "orcid": "0000-0002-0570-861X"
    },
    {
      "affs": [
        0,
        2
      ],
      "name": "Alexander Paz",
      "orcid": "0000-0002-5804-4781"
    },
    {
      "affs": [
        0
      ],
      "name": "Amir Esrafilian",
      "orcid": "0000-0002-8321-8528"
    },
    {
      "affs": [
        0
      ],
      "name": "Lauri Stenroth",
      "orcid": "0000-0002-7705-9188"
    },
    {
      "affs": [
        0
      ],
      "name": "Will Bosch",
      "orcid": "0000-0002-8955-9892"
    },
    {
      "affs": [
        0
      ],
      "name": "Mika E Mononen"
    },
    {
      "affs": [
        3
      ],
      "name": "Marius Henriksen"
    },
    {
      "affs": [
        3,
        4
      ],
      "name": "Tine Alkjaer",
      "orcid": "0000-0002-9105-3882"
    },
    {
      "affs": [
        1
      ],
      "name": "Hanna Isaksson",
      "orcid": "0000-0002-9690-8907"
    },
    {
      "affs": [
        0,
        5,
        6
      ],
      "name": "Rami K Korhonen"
    },
    {
      "affs": [
        0,
        7
      ],
      "name": "Petri Tanska",
      "orcid": "0000-0002-9684-6902"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/51ta0pppnf7y5.bib",
  "cited_by": 0,
  "doi": "10.1002/jor.70324",
  "fulltext_url": "https://europepmc.org/articles/PMC13801329",
  "id": "51ta0pppnf7y5",
  "issns": [
    "0736-0266",
    "1554-527X"
  ],
  "landing_url": "https://europepmc.org/article/MED/43083400",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2746|Knee injuries and reconstruction techniques"
    ]
  ],
  "openalex": "W7239899441",
  "pdf_url": "https://europepmc.org/articles/PMC13801329?pdf=render",
  "pmcid": "PMC13801329",
  "pmid": "43083400",
  "published": "2026-11-26",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/51ta0pppnf7y5.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T15:22:40Z",
      "native_id": "MED:43083400",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43083400"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2746|Knee injuries and reconstruction techniques",
      "subfield": "surgery"
    }
  ],
  "title": "Generalized Gait Inputs Bias Predicted Meniscal Mechanics in Subject-Specific Knee Joint Finite Element Models.",
  "title_text": "Generalized Gait Inputs Bias Predicted Meniscal Mechanics in Subject-Specific Knee Joint Finite Element Models.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:22:40Z",
  "url": "https://research.draconitic.com/paper/51ta0pppnf7y5",
  "venue": "Journal of orthopaedic research : official publication of the Orthopaedic Research Society",
  "versions": []
}