  "abstract": "The growing use of hypofractionated radiotherapy and reirradiation has increased the need for voxel-based conversion of hypofractionated dose distributions to conventional-fractionation equivalents for organ-at-risk (OAR) dose-constraint evaluation. Some voxel-based approaches apply a uniform equivalent dose in 2 Gy fractions (EQD2) to all voxels, which may not fully reproduce the dose characteristics of conventional fractionated radiotherapy, where dose per fraction decreases below 2 Gy with increasing distance from the target. Moreover, use of voxel-based conversion approaches requires validation against established OAR dose constraints. Twelve thoracic ultra-hypofractionated treatment plans prescribed in five fractions were converted using To2GyConstraints version 1.0 (Healthy Innovations, Rachiine, Zgharta, Lebanon; www.healthy-innovations.com), a cloud-based software tool that performs dose-range-dependent voxel-based biological dose conversion from hypofractionated to conventional fractionation. It applies dose-range-dependent models: linear-quadratic-linear (LQ-L)-based EQD2 for high-dose voxels, linear-quadratic (LQ)-based EQD2 for intermediate-dose voxels, and equivalent dose in x Gy fractions (EQDx) for low-dose voxels. Original and converted dose distributions were evaluated using corresponding OAR constraints for their respective fractionation regimens. Constraint-violation status was compared using the original ultra-hypofractionated assessment as the reference. An updated standardized data-collection template incorporating thoracic OAR constraints was developed for future multicenter evaluation. The pilot evaluation demonstrated feasibility and showed promising agreement in OAR constraint-violation assessment between original and converted dose distributions. The standardized workflow provides a framework for multicenter evaluation. Dose-range-dependent voxel-based biological dose conversion using To2GyConstraints is feasible for thoracic ultra-hypofractionated radiotherapy. By accounting for radiobiological behavior across different dose ranges, this approach may improve the representation of conventional-fractionation equivalents for OAR assessment. Larger multicenter evaluation is warranted.",
  "abstract_shown": true,
  "affiliations": [
    "Research and Development Department, Healthy Innovations, Rachiine, LBN.",
    "Medical Imaging Department, Holy Family University, Batroun, LBN.",
    "Radiation Oncology Department, Tripoli Governmental Hospital and Doctors Center, Tripoli, LBN.",
    "Radiation Oncology Department, American University of Beirut Medical Center, Beirut, LBN."
  ],
  "article_type": "other",
  "arxiv": null,
  "author_total": 7,
  "authors": [
    {
      "affs": [
        0,
        1,
        2
      ],
      "name": "Mazen Moussallem"
    },
    {
      "affs": [
        3
      ],
      "name": "Wassim Jalbout"
    },
    {
      "affs": [
        2
      ],
      "name": "Dima Mahmoud"
    },
    {
      "affs": [
        3
      ],
      "name": "Bassem Youssef"
    },
    {
      "affs": [
        3
      ],
      "name": "Zeinab Reda"
    },
    {
      "affs": [
        3
      ],
      "name": "Maroun Al Beainy"
    },
    {
      "affs": [
        0
      ],
      "name": "Antoine Nassif"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/5egjebcwh4rfj.bib",
  "cited_by": 0,
  "doi": "10.7759/cureus.118239",
  "fulltext_url": "https://europepmc.org/articles/PMC13784312",
  "id": "5egjebcwh4rfj",
  "issns": [
    "2168-8184"
  ],
  "landing_url": "https://europepmc.org/article/MED/43061562",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Healthcare Technology"
    ],
    [
      "heading",
      "Medical Physics"
    ],
    [
      "heading",
      "Radiation Oncology"
    ],
    [
      "openalex",
      "3108|Advanced Radiotherapy Techniques"
    ]
  ],
  "openalex": "W7223006515",
  "pdf_url": "https://europepmc.org/articles/PMC13784312?pdf=render",
  "pmcid": "PMC13784312",
  "pmid": "43061562",
  "published": "2026-10-20",
  "publisher": "Cureus Inc.",
  "ris": "https://research.draconitic.com/paper/5egjebcwh4rfj.ris",
  "sources": [
    {
      "first_seen": "2026-11-21T15:23:37Z",
      "native_id": "MED:43061562",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43061562"
    },
    {
      "first_seen": "2026-11-23T12:22:55Z",
      "native_id": "PMC13784312",
      "source": "pmc",
      "url": "https://doi.org/10.7759/cureus.118239"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "heading:Medical Physics",
      "subfield": "biological-medical"
    }
  ],
  "title": "Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.",
  "title_text": "Dose-Range-Dependent Voxel-Based Biological Dose Conversion From Thoracic Ultra-Hypofractionation to Conventional Fractionation: A Pilot Evaluation and Framework for Future Multicenter Studies.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-23T12:22:55Z",
  "url": "https://research.draconitic.com/paper/5egjebcwh4rfj",
  "venue": "Cureus",
  "versions": []
}