  "abstract": "Isotope ratios underpin tracer studies of transport in oxides, battery materials, and biological systems, yet time-of-flight secondary ion mass spectrometry (ToF-SIMS) struggles to quantify ratios whose members differ in intensity by orders of magnitude: a primary-ion pulse long enough to count the minor isotope precisely can saturate the major isotope, whereas a pulse short enough to keep the major isotope linear yields too few minor-isotope counts. We show that multi-pulse-width acquisition yields quantitative isotope ratios when a dose factor measured within each crater links the phases and each isotope is taken only from phases in which it remains linear; we call this quantitative reconstruction interleaved-pulse acquisition. Pulse widths are selected from measured transfer curves and peak shapes. On thermal SiO2, a tuned (6, 35) ns pair achieves the same per-layer precision as short-pulse acquisition with a 13-fold reduction in the number of analysis frames. On 18O-enriched WOx films, interleaving extends the quantifiable range at the low-fraction end by about 14-fold. Across isotope ratios spanning approximately 1:500 to 1:1, the interleaved reconstruction agrees with the corresponding linear reference measurements, showing no measurable bias introduced by interleaving, and natural-abundance ratios of oxygen, strontium and titanium are reproduced within several percent. The method requires no hardware additions and enables depth-resolved isotope-ratio measurements over a wide range within a single crater.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": "2609.37413",
  "author_total": 1,
  "authors": [
    {
      "name": "Anton V. Ievlev"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/5hafn45xkc4f3.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2609.37413",
  "fulltext_url": null,
  "id": "5hafn45xkc4f3",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2609.37413",
  "language": null,
  "licence": "LicenseRef-arXiv-nonexclusive-1.0",
  "licence_label": "arXiv licence",
  "licence_source": "article",
  "licence_url": "http://arxiv.org/licenses/nonexclusive-distrib/1.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "cond-mat.mtrl-sci"
    ],
    [
      "arxiv",
      "physics.ins-det"
    ],
    [
      "openalex",
      "2206|Ion-surface interactions and analysis"
    ]
  ],
  "openalex": "W7214935046",
  "pdf_url": "https://arxiv.org/pdf/2609.37413",
  "pmcid": null,
  "pmid": null,
  "published": "2026-09-29",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/5hafn45xkc4f3.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:25:31Z",
      "native_id": "2609.37413",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2609.37413"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "arxiv:physics.ins-det",
      "subfield": "applied-instrumentation"
    },
    {
      "field": "physics",
      "origin": "arxiv:cond-mat.mtrl-sci",
      "subfield": "condensed-matter"
    }
  ],
  "title": "Quantitative Interleaved-Pulse Acquisition Extends the Range of Isotope-Ratio Measurements in ToF-SIMS",
  "title_text": "Quantitative Interleaved-Pulse Acquisition Extends the Range of Isotope-Ratio Measurements in ToF-SIMS",
  "type": "preprint",
  "updated_at": "2026-10-30T12:25:31Z",
  "url": "https://research.draconitic.com/paper/5hafn45xkc4f3",
  "venue": "arXiv",
  "versions": []
}