{
  "abstract": "Charge state assignment is a critical step in many workflows for intact protein analysis by mass spectrometry. Computational deconvolution algorithms are increasingly used to automate data analysis, but conventional approaches can present artifacts. Here, we explore several approaches to remove artifacts by limiting the charge state assignments for each data point. One approach removes satellite charge states surrounding local maxima. Another removes harmonics at double a more probable charge assignment. The last two limit either the total number of allowed charge state assignments or the minimum relative charge state assignment probability for a given data point. These new features are as effective as the prior SoftMax artifact removal in UniDec, but they enable easier tuning by the user. Although the new set of features introduces additional complexity and an expanded number of parameters, these tools enable users to more precisely reduce artifacts in deconvolution results.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Chemistry",
    "University of Texas at Austin"
  ],
  "article_type": null,
  "arxiv": null,
  "author_total": 1,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Michael T. Marty",
      "orcid": "0000-0001-8115-1772"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/5khbaektzpm2s.bib",
  "cited_by": 0,
  "doi": "10.26434/chemrxiv.15009546/v1",
  "fulltext_url": null,
  "id": "5khbaektzpm2s",
  "issns": [],
  "landing_url": "https://chemrxiv.org/doi/full/10.26434/chemrxiv.15009546/v1",
  "language": null,
  "licence": "CC-BY-NC-ND",
  "licence_label": "CC BY-NC-ND",
  "licence_source": "journal",
  "licence_url": "https://creativecommons.org/licenses/by-nc-nd/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "1607|Mass Spectrometry Techniques and Applications"
    ]
  ],
  "openalex": "W7214581683",
  "pdf_url": "https://chemrxiv.org/doi/pdf/10.26434/chemrxiv.15009546/v1",
  "pmcid": null,
  "pmid": null,
  "published": "2026-09-28",
  "publisher": "American Chemical Society (ACS)",
  "ris": "https://research.draconitic.com/paper/5khbaektzpm2s.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:17:21Z",
      "native_id": "10.26434/chemrxiv.15009546",
      "source": "chemrxiv",
      "url": "https://chemrxiv.org/doi/full/10.26434/chemrxiv.15009546/v3"
    }
  ],
  "subjects": [
    {
      "field": "chemistry",
      "origin": "openalex:1607|Mass Spectrometry Techniques and Applications",
      "subfield": "physical"
    }
  ],
  "title": "Revisiting Artifact Suppression in Electrospray Ionization Deconvolution",
  "title_text": "Revisiting Artifact Suppression in Electrospray Ionization Deconvolution",
  "type": "preprint",
  "updated_at": "2026-10-31T00:20:31Z",
  "url": "https://research.draconitic.com/paper/5khbaektzpm2s",
  "venue": "ChemRxiv",
  "versions": []
}