{
  "abstract": "Models for colorectal polyp classification lose accuracy when applied to images from a different clinical center, and training on the low-frequency approximation subband of a discrete wavelet transform has been proposed as a remedy. We set out to test that hypothesis on Kvasir-SEG and PICCOLO, and report instead that three measurement practices common in this literature do not support the conclusions drawn from them. First, a single-level Haar LL subband is arithmetically identical to grayscale conversion followed by 2× decimation, verified to floating-point precision on both random and endoscopic data. At one decomposition level, wavelet decomposition and resolution reduction are not separable hypotheses, and the proposed mechanism is therefore not well-formed as posed. Second, image-level splitting—the standard remedy for patch-level leakage—is insufficient for video-derived datasets. PICCOLO's 3,433 frames derive from 70 physical lesions in 40 examinations; an image-level split leaves 58 of those lesions and 37 of those videos shared between training and test, and in-distribution AUC falls by 0.054 when measured against the partition the dataset authors supply. Third, the intersection-over-union metric used to assess attention localization inverts on high-coverage patches, where a polyp patch is almost entirely polyp: random attention scores 0.59 against 0.24 for trained heads. Measured without the area confound, localization is real but weak and confined to particular heads. We additionally quantify a reproducibility floor. In small models trained from scratch, runs receiving bit-identical inputs diverge by up to 0.177 AUC in the CNN/PICCOLO row through early-stopping checkpoint selection, and in one experimental arm this null control is itself statistically significant, so no claim from that arm is supportable at any p-value. A color-removal benefit observed in this regime (+0.067 AUC, 95% CI [+0.037, +0.097]) does not replicate on ImageNet-pretrained ResNet-18 and DeiT-Tiny backbones, where intervals exclude effects a fifth its size. We recommend reporting a null control alongside every comparison, and show that this identifies arms in which no claim can be supported.",
  "abstract_shown": true,
  "affiliations": [
    "School of Electronics Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu, India",
    "Computer Science and Engineering Indian Institute of Information Technology, Kottayam, Kerala, India"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 6,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Jenifer R."
    },
    {
      "affs": [
        0
      ],
      "name": "Dhimant Tewari"
    },
    {
      "affs": [
        0
      ],
      "name": "Goutham Veerapu"
    },
    {
      "affs": [
        1
      ],
      "name": "Nisha J. S."
    },
    {
      "affs": [
        0
      ],
      "name": "Gopinath Palanisamy"
    },
    {
      "affs": [
        0
      ],
      "name": "Saanji Kohli"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/5pvwqs39yh4y6.bib",
  "cited_by": 0,
  "doi": "10.3389/frai.2026.1929384",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13790038/",
  "id": "5pvwqs39yh4y6",
  "issns": [
    "2624-8212"
  ],
  "landing_url": "https://doi.org/10.3389/frai.2026.1929384",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Original Research"
    ],
    [
      "openalex",
      "2730|Colorectal Cancer Screening and Detection"
    ]
  ],
  "openalex": "W7225643073",
  "pdf_url": "https://www.frontiersin.org/journals/artificial-intelligence/articles/10.3389/frai.2026.1929384/pdf",
  "pmcid": "PMC13790038",
  "pmid": "43075073",
  "published": "2026-11-09",
  "publisher": "Frontiers Media SA",
  "ris": "https://research.draconitic.com/paper/5pvwqs39yh4y6.ris",
  "sources": [
    {
      "first_seen": "2026-11-25T12:22:46Z",
      "native_id": "PMC13790038",
      "source": "pmc",
      "url": "https://doi.org/10.3389/frai.2026.1929384"
    },
    {
      "first_seen": "2026-11-25T15:20:05Z",
      "native_id": "MED:43075073",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43075073"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2730|Colorectal Cancer Screening and Detection",
      "subfield": "oncology"
    }
  ],
  "title": "Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification",
  "title_text": "Single-level wavelet preprocessing is downsampling: measurement failures in cross-dataset polyp classification",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T12:22:06Z",
  "url": "https://research.draconitic.com/paper/5pvwqs39yh4y6",
  "venue": "Frontiers in Artificial Intelligence",
  "versions": []
}