{
  "abstract": "Background : As value-based care and sustainability increasingly shape clinical practice, foot and ankle imaging must balance diagnostic efficacy, patient safety, environmental impact, and cost. However, few studies have calculated and compared lower-extremity radiographs (XR), standard lower-extremity computed tomography (CT), and weightbearing CT (WBCT) across radiation, cost, and carbon emissions. We aimed to compare radiation exposure, procedural cost, and carbon emissions across XR, CT, and WBCT. Methods: This retrospective chart review assessed 25 WBCTs, 25 CTs, and 25 XRs from adults evaluated for Weber B ankle fractures with congruent mortise. Radiation exposure was calculated from dosage reports and compared with pairwise tests. Scanner electricity use values (both measured and literature derived) estimated carbon emissions. Costs were determined by time-driven activity-based costing (TDABC). Results: With the numbers available, no significant difference in radiation could be detected between WBCT and XR (0.004 [IQR 0.004-0.004] vs 0.003 [IQR 0.002-0.005] mSv, P = .12), but both were lower than CT ( P < .001). WBCT showed intermediate costs ($28.14) and carbon emissions (0.07 kg CO 2 e) compared with XR ($13.98, 0.06 kg CO 2 e) and CT ($37.79, 0.30 kg CO 2 e) the lowest cost and carbon emissions compared with CT and WBCT. Standard CT had the highest values across modalities. Conclusion: Although XR remains a favorable preliminary imaging option, WBCT’s lower radiation dose, cost, and carbon emissions compared with CT may support considering WBCT as an advanced imaging alternative to standard CT in adults with Weber B ankle fractures and a congruent mortise, where WBCT is available. Level of Evidence: Level III, retrospective comparative study.",
  "abstract_shown": true,
  "affiliations": [
    "Foot & Ankle Research and Innovation Laboratory (FARIL), Department of Orthopedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA",
    "Foot and Ankle Division, Department of Orthopaedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA"
  ],
  "article_type": null,
  "arxiv": null,
  "author_total": 8,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Justin Luk BS"
    },
    {
      "affs": [
        0
      ],
      "name": "Robin Hu BS"
    },
    {
      "affs": [
        0
      ],
      "name": "Julia Remlinger BS"
    },
    {
      "affs": [
        0
      ],
      "name": "Rohith Ryali BA"
    },
    {
      "affs": [
        0
      ],
      "name": "Mani Eftekhari BS"
    },
    {
      "affs": [
        1
      ],
      "name": "Soheil Ashkani-Esfahani MD, MPH"
    },
    {
      "affs": [
        1
      ],
      "name": "Eric M. Bluman MD, PhD"
    },
    {
      "affs": [
        1
      ],
      "name": "Jeremy T. Smith MD"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/641xg3gzzwmjx.bib",
  "cited_by": 0,
  "doi": "10.1177/24730114261504445",
  "fulltext_url": "https://doi.org/10.1177/24730114261504445",
  "id": "641xg3gzzwmjx",
  "issns": [
    "2473-0114"
  ],
  "landing_url": "https://doi.org/10.1177/24730114261504445",
  "language": "en",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "journal",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "lcc",
      "RD701-811"
    ],
    [
      "openalex",
      "2741|Radiation Dose and Imaging"
    ]
  ],
  "openalex": "W7236586082",
  "pdf_url": null,
  "pmcid": null,
  "pmid": null,
  "published": "2026-11-19",
  "publisher": "SAGE Publishing",
  "ris": "https://research.draconitic.com/paper/641xg3gzzwmjx.ris",
  "sources": [
    {
      "first_seen": "2026-11-20T18:20:40Z",
      "native_id": "1254ed30507c4c4eb34ff0f95ea4e91a",
      "source": "doaj",
      "url": "https://doi.org/10.1177/24730114261504445"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2741|Radiation Dose and Imaging",
      "subfield": "imaging"
    }
  ],
  "title": "Sustainable Diagnostics: A Comparative Analysis of Radiation, Carbon Emissions, and the Cost of Weightbearing CT, Radiography, and Standard CT in Weber B Ankle Fracture Imaging; a Short Report",
  "title_text": "Sustainable Diagnostics: A Comparative Analysis of Radiation, Carbon Emissions, and the Cost of Weightbearing CT, Radiography, and Standard CT in Weber B Ankle Fracture Imaging; a Short Report",
  "type": "peer-reviewed",
  "updated_at": "2026-11-21T18:20:55Z",
  "url": "https://research.draconitic.com/paper/641xg3gzzwmjx",
  "venue": "Foot & Ankle Orthopaedics",
  "versions": []
}