{
  "abstract": "Nanomedicine development is constrained less by a shortage of candidate materials than by weak coupling among formulation design, reproducible manufacturing, and biologically informative validation. This review examines how artificial intelligence (AI)-enabled design, microfluidic manufacturing, and tiered biological testing can be integrated into a design-manufacture-test-learn (DMTL) framework. We focus on the interfaces linking design descriptors and critical material attributes to critical process parameters, distribution-resolved and longitudinal critical quality attributes (CQAs), biological dose metrics, functional endpoints, and model updates. Particular attention is given to feasibility-constrained inverse design; nanoparticle heterogeneity at the single-particle and subpopulation levels; time-dependent channel fouling and process drift; cross-platform dose normalization; storage stability and cold-chain resilience; and the fit-for-purpose use of organ-on-a-chip systems. Quantitative benchmarking of representative primary studies indicates that current evidence is strongest at the component and partial-loop levels, with reported advances in model-guided formulation selection, process-CQA prediction, prospective experimental validation, and mechanism-relevant biological testing. However, direct comparisons remain limited by heterogeneity in datasets, validation strategies, manufacturing conditions, assay formats, and biological endpoints. Repeated end-to-end DMTL cycles integrating uncertainty-aware model updating, controlled and traceable manufacturing, mechanism-relevant testing, independent external validation, and prespecified stopping criteria have not yet been demonstrated. To distinguish conceptual integration from measurable closed-loop performance, we propose a five-level maturity model, a minimum reporting set, and a four-domain scoring framework encompassing design intelligence, process intelligence, biological fidelity, and translational readiness. This evidence-calibrated framework delineates the current evidence boundary and provides practical criteria for designing, comparing, and validating future closed-loop nanomedicine platforms.",
  "abstract_shown": true,
  "affiliations": [
    "College of Pharmacy, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, 550025, China.",
    "Department of Biomedical Sciences, Faculty of Medicine, Macau University of Science and Technology, Avenida Wai Long, Taipa, Macau, China.",
    "College of Traditional Chinese Medicine, Guangdong Pharmaceutical University, Guangzhou, 510006, Guangdong, China.",
    "College of Life Sciences and Biopharmaceuticals, Guangdong Pharmaceutical University, Guangzhou, 510006, Guangdong, China. yuanyuanhaida@126.com.",
    "College of Pharmacy, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, 550025, China. pyxmarx@126.com.",
    "College of Pharmacy, Guangdong Medical University, Dongguan, 523808, Guangdong, China. pyxmarx@126.com."
  ],
  "article_type": "review article",
  "arxiv": null,
  "author_total": 12,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Kai-Lang Mu"
    },
    {
      "affs": [
        0
      ],
      "name": "Rui-Qi Liao"
    },
    {
      "affs": [
        0
      ],
      "name": "Chang-Mao Guo"
    },
    {
      "affs": [
        0
      ],
      "name": "Su Chen"
    },
    {
      "affs": [
        0
      ],
      "name": "Jun-Li Xie"
    },
    {
      "affs": [
        0
      ],
      "name": "Yu-Chen Liu"
    },
    {
      "affs": [
        0
      ],
      "name": "Gang Liu"
    },
    {
      "affs": [
        0
      ],
      "name": "Zhi-Gang Ju"
    },
    {
      "affs": [
        1
      ],
      "name": "Bing-Nan Liu"
    },
    {
      "affs": [
        2
      ],
      "name": "Xiao-Min Tang"
    },
    {
      "affs": [
        3
      ],
      "name": "Yuan Yuan"
    },
    {
      "affs": [
        4,
        5
      ],
      "name": "Yu-Xin Pang"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/64f68c4r61sbr.bib",
  "cited_by": 1,
  "doi": "10.1186/s12951-026-04921-1",
  "fulltext_url": "https://europepmc.org/articles/PMC13753107",
  "id": "64f68c4r61sbr",
  "issns": [
    "1477-3155"
  ],
  "landing_url": "https://europepmc.org/article/MED/43009972",
  "language": "eng",
  "licence": "CC-BY-NC-ND",
  "licence_label": "CC BY-NC-ND",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc-nd/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Review"
    ],
    [
      "openalex",
      "2502|Nanoparticle-Based Drug Delivery"
    ]
  ],
  "openalex": "W7203471121",
  "pdf_url": "https://europepmc.org/articles/PMC13753107?pdf=render",
  "pmcid": "PMC13753107",
  "pmid": "43009972",
  "published": "2026-08-14",
  "publisher": "BMC",
  "ris": "https://research.draconitic.com/paper/64f68c4r61sbr.ris",
  "sources": [
    {
      "first_seen": "2026-11-12T15:22:43Z",
      "native_id": "MED:43009972",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43009972"
    },
    {
      "first_seen": "2026-11-15T12:22:18Z",
      "native_id": "PMC13753107",
      "source": "pmc",
      "url": "https://doi.org/10.1186/s12951-026-04921-1"
    }
  ],
  "subjects": [
    {
      "field": "chemistry",
      "origin": "openalex:2502|Nanoparticle-Based Drug Delivery",
      "subfield": "materials-polymers"
    }
  ],
  "title": "Toward closed-loop engineering of nanomedicines: integrating AI-enabled design, microfluidic manufacturing, and organ-on-a-chip validation.",
  "title_text": "Toward closed-loop engineering of nanomedicines: integrating AI-enabled design, microfluidic manufacturing, and organ-on-a-chip validation.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-15T12:22:18Z",
  "url": "https://research.draconitic.com/paper/64f68c4r61sbr",
  "venue": "Journal of nanobiotechnology",
  "versions": []
}