  "abstract": "ALFE2 is a front-end ASIC developed for the ATLAS Liquid Argon (LAr) Calorimeter upgrade during the High-Luminosity Large Hadron Collider (HL-LHC) phase. ALFE2 comprises four preamplifier/shaper channels, each providing two distinct gain outputs to cover a 16-bit dynamic range. A robotic system has been developed for the automatic quality control test of ALFE2, and over 10% of the 80,000 chips have been evaluated by September 2025. The evaluation has allowed us to establish grading criteria. Using these criteria, a yield of over 85% was achieved in the evaluation tests, and these criteria are now being applied to the ongoing full-production QC. Irradiation tests were also performed for the quality assurance of ALFE2. No significant performance degradation was observed during the total-ionizing-dose (TID) test. Based on the single-event effect (SEE) test results, an error rate of fewer than 4.6 single-event upsets (SEUs) per day is extrapolated for the entire ATLAS LAr Calorimeter during HL-LHC operation.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": "Journal reference: 2026 JINST 21 P08025",
  "arxiv": "2607.10458",
  "author_total": 20,
  "authors": [
    {
      "name": "E. Buschmann"
    },
    {
      "name": "G. Carini"
    },
    {
      "name": "G. Chatzianastasiou"
    },
    {
      "name": "H. Chen"
    },
    {
      "name": "Y. Chen"
    },
    {
      "name": "M. Dabrowski"
    },
    {
      "name": "G. Deptuch"
    },
    {
      "name": "L. Duflot"
    },
    {
      "name": "M. Feo"
    },
    {
      "name": "J. Kierstead"
    },
    {
      "name": "T. Liu"
    },
    {
      "name": "H. Ma"
    },
    {
      "name": "D. Matakias"
    },
    {
      "name": "N. Morange"
    },
    {
      "name": "M. Oliveira"
    },
    {
      "name": "S. Rescia"
    },
    {
      "name": "E. Rossi"
    },
    {
      "name": "S. Tang"
    },
    {
      "name": "M. Tamari"
    },
    {
      "name": "H. Xu"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/678exp87ct44t.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2607.10458",
  "fulltext_url": null,
  "id": "678exp87ct44t",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2607.10458",
  "language": null,
  "licence": "LicenseRef-arXiv-nonexclusive-1.0",
  "licence_label": "arXiv licence",
  "licence_source": "article",
  "licence_url": "http://arxiv.org/licenses/nonexclusive-distrib/1.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "hep-ex"
    ],
    [
      "arxiv",
      "physics.ins-det"
    ]
  ],
  "openalex": null,
  "pdf_url": "https://arxiv.org/pdf/2607.10458",
  "pmcid": null,
  "pmid": null,
  "published": "2026-08-17",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/678exp87ct44t.ris",
  "sources": [
    {
      "first_seen": "2026-11-10T06:21:23Z",
      "native_id": "2607.10458",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2607.10458"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "arxiv:physics.ins-det",
      "subfield": "applied-instrumentation"
    },
    {
      "field": "physics",
      "origin": "arxiv:hep-ex",
      "subfield": "high-energy"
    }
  ],
  "title": "Quality control and quality assurance evaluation of ALFE2, a large-dynamic-range front-end ASIC de-veloped for the ATLAS Liquid Argon Calorimeter high-luminosity LHC upgrade",
  "title_text": "Quality control and quality assurance evaluation of ALFE2, a large-dynamic-range front-end ASIC de-veloped for the ATLAS Liquid Argon Calorimeter high-luminosity LHC upgrade",
  "type": "preprint",
  "updated_at": "2026-11-10T06:21:23Z",
  "url": "https://research.draconitic.com/paper/678exp87ct44t",
  "venue": "arXiv",
  "versions": [
    {
      "doi": "10.1088/1748-0221/21/08/p08025",
      "pid": null,
      "relation": "published-as",
      "title": null,
      "venue": null
    }
  ]
}