{
  "abstract": "Purpose\n\nTo evaluate the feasibility of contrast sensitivity (CS) testing using a head-mounted binocular perimeter (IMO vifa) and to describe postoperative CS in eyes implanted with three types of intraocular lenses (IOLs).Patients and methods\n\nThis retrospective single-center study included 102 eyes of 71 patients who underwent uncomplicated cataract surgery with implantation of a segmented refractive IOL (Lentis Comfort [LC], 38 eyes), an enhanced monofocal IOL (Tecnis Eyhance DIB00V [DIB], 33 eyes), or a standard monofocal IOL (Tecnis DCB00V [DCB], 31 eyes). CS was measured in each eye with both eyes open under photopic room lighting 1 month postoperatively, and the area under the log CS function (AULCSF) was calculated. Groups were compared using age-adjusted linear regression accounting for inter-eye correlation.Results\n\nTesting required approximately 5 min per patient. Mean AULCSF was 1.35 ± 0.27, 1.19 ± 0.26, and 1.30 ± 0.24 in the LC, DIB, and DCB groups, respectively. No statistically significant difference was detected among the groups after age adjustment (p = 0.304). Compared with DCB, the adjusted differences were 0.017 (95% CI -0.113 to 0.148) for LC and -0.082 (95% CI -0.213 to 0.049) for DIB.Conclusion\n\nCS testing with the IMO vifa was feasible at routine postoperative visits under ambient room lighting. Further prospective studies are needed to assess its repeatability and agreement with established CS tests.",
  "abstract_shown": true,
  "affiliations": [
    "Oki Eye Center, Sojukai Medical Foundation, Tokyo, Japan.",
    "Department of Ophthalmology, Jikei University School of Medicine, Tokyo, Japan."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 6,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Tetsutaro Oki",
      "orcid": "0000-0002-2910-1839"
    },
    {
      "affs": [
        1
      ],
      "name": "Koji Komatsu",
      "orcid": "0000-0002-0917-2760"
    },
    {
      "affs": [
        0
      ],
      "name": "Yuri Shinohe"
    },
    {
      "affs": [
        1
      ],
      "name": "Yoshiaki Kabata"
    },
    {
      "affs": [
        0
      ],
      "name": "Kotaro Oki"
    },
    {
      "affs": [
        1
      ],
      "name": "Tadashi Nakano",
      "orcid": "0000-0002-3184-1991"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/6rv12pxcj6rrm.bib",
  "cited_by": 0,
  "doi": "10.2147/opth.s644954",
  "fulltext_url": "https://europepmc.org/articles/PMC13680136",
  "id": "6rv12pxcj6rrm",
  "issns": [
    "1177-5467",
    "1177-5483"
  ],
  "landing_url": "https://europepmc.org/article/MED/42903087",
  "language": "eng",
  "licence": "CC-BY-NC",
  "licence_label": "CC BY-NC",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2731|Intraocular Surgery and Lenses"
    ]
  ],
  "openalex": "W7221835948",
  "pdf_url": "https://europepmc.org/articles/PMC13680136?pdf=render",
  "pmcid": "PMC13680136",
  "pmid": "42903087",
  "published": "2026-10-15",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/6rv12pxcj6rrm.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:19:53Z",
      "native_id": "MED:42903087",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/42903087"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2731|Intraocular Surgery and Lenses",
      "subfield": "general"
    }
  ],
  "title": "Preliminary Feasibility of Contrast Sensitivity Testing Using the IMO vifa Perimeter After Cataract Surgery.",
  "title_text": "Preliminary Feasibility of Contrast Sensitivity Testing Using the IMO vifa Perimeter After Cataract Surgery.",
  "type": "peer-reviewed",
  "updated_at": "2026-10-30T12:19:53Z",
  "url": "https://research.draconitic.com/paper/6rv12pxcj6rrm",
  "venue": "Clinical ophthalmology (Auckland, N.Z.)",
  "versions": []
}