{
  "abstract": "Aims: Pulsed field ablation (PFA) is a ablation modality that is increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF) patients. This study assessed the safety and effectiveness of a balloon-based PFA system at 6 months after treatment.\n\nMethods and results: This study is a prospective, single-center, premarket study. A total of 56 patients with drug-refractory paroxysmal atrial fibrillation (PAF) were enrolled between November 2024 and September 2025 and underwent PVI with a balloon-based PFA system. The study endpoints were the rate of primary serious adverse events, acute procedural effectiveness and 6-month freedom from recurrence. Acute effectiveness was achieved in 100% (231/231) of the treated PVs (100% of patients, 56/56), with 33 ± 5.5 PFA applications/patient. The procedure, fluoroscopy, and transpired ablation times were 89.0 ± 30.7, 24.2 ± 8.3, and 20.0 ± 12.0 min, respectively. One (1.8%; 1/56) primary serious adverse event occurred: one patient developed intraoperative gastrointestinal bleeding due to TEE-induced mechanical injury. One patient developed a cerebral infarction on postoperative Day 28. The rate of freedom from documented atrial arrhythmias was 92.9% through 6 months after the index procedure.\n\nConclusion: The primary results of this study demonstrate the safety and effectiveness of the balloon-based PFA system for performing PVI in patients with PAF.\n\nSupplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02417-4.",
  "abstract_shown": true,
  "affiliations": [
    "TEDA International Cardiovascular Hospital, Tianjin, China"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 10,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Peize Wang"
    },
    {
      "affs": [
        0
      ],
      "name": "Kun Zhang"
    },
    {
      "affs": [
        0
      ],
      "name": "Jinlong Bai"
    },
    {
      "affs": [
        0
      ],
      "name": "Xiuhong Dong"
    },
    {
      "affs": [
        0
      ],
      "name": "Shuai Yang"
    },
    {
      "affs": [
        0
      ],
      "name": "Lichao Tian"
    },
    {
      "affs": [
        0
      ],
      "name": "Zhaoqian Zhang"
    },
    {
      "affs": [
        0
      ],
      "name": "Zhi Li"
    },
    {
      "affs": [
        0
      ],
      "name": "Yuhao Miao"
    },
    {
      "affs": [
        0
      ],
      "name": "Jingjing Liu"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/7412rtz6106cn.bib",
  "cited_by": 0,
  "doi": "10.1007/s10840-026-02417-4",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13769747/",
  "id": "7412rtz6106cn",
  "issns": [
    "1383-875X",
    "1572-8595"
  ],
  "landing_url": "https://doi.org/10.1007/s10840-026-02417-4",
  "language": "en",
  "licence": "CC-BY-NC-ND-4.0",
  "licence_label": "CC BY-NC-ND 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc-nd/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Research"
    ],
    [
      "openalex",
      "2705|Atrial Fibrillation Management and Outcomes"
    ]
  ],
  "openalex": "W7160139333",
  "pdf_url": "https://link.springer.com/content/pdf/10.1007/s10840-026-02417-4.pdf",
  "pmcid": "PMC13769747",
  "pmid": "42616314",
  "published": "2026-08-19",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/7412rtz6106cn.ris",
  "sources": [
    {
      "first_seen": "2026-11-18T12:21:38Z",
      "native_id": "PMC13769747",
      "source": "pmc",
      "url": "https://doi.org/10.1007/s10840-026-02417-4"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2705|Atrial Fibrillation Management and Outcomes",
      "subfield": "cardiovascular"
    }
  ],
  "title": "Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation",
  "title_text": "Safety and feasibility of a balloon-based pulsed field ablation system for the catheter ablation of paroxysmal atrial fibrillation",
  "type": "peer-reviewed",
  "updated_at": "2026-11-19T12:20:50Z",
  "url": "https://research.draconitic.com/paper/7412rtz6106cn",
  "venue": "Journal of Interventional Cardiac Electrophysiology",
  "versions": []
}