{
  "abstract": "Background\n\nMonitoring expired end-tidal carbon dioxide (CO₂) is crucial for sedated patients undergoing various procedures. However, a significant concern is the potential contamination of CO₂ sampling lines and gas analyzers when used on patients with respiratory tract infections. To address this, a novel antiviral filter was developed featuring an antimicrobial compound synthesized from cashew skin and husks. Our study aims to assess the device's clinical feasibility for continuous end-tidal CO₂ monitoring.Methods\n\nWe conducted a preliminary assessment on 15 adult patients undergoing minor upper limb surgical procedures with local anesthesia, where continuous end-tidal CO₂ monitoring is essential. In all cases, the antiviral filter was positioned above the patient's simple face mask and remained there throughout the entire procedure. The primary outcome was the incidence end-tidal CO₂ capnogram signal disruptions. The secondary outcome was the occurrence of any patient-reported adverse events during device utilization.Results\n\nThe median [range] duration of end-tidal CO₂ monitoring using the antiviral filter was 25 [12-38] minutes. Independent observers found no disruptions in the continuous end-tidal CO₂ capnograms across all patients. Furthermore, no patients reported any discomfort or foul smell from the antiviral filter.Conclusion\n\nThis pilot feasibility study demonstrates the antiviral filter's potential as an inexpensive, effective, and reliable device for end-tidal CO₂ monitoring in clinical setting. Our findings also advocate for its role in promoting sustainable healthcare practices.",
  "abstract_shown": true,
  "affiliations": [
    "Division of Anaesthesiology and Perioperative Medicine, Singapore General Hospital, Outram Road, Singapore, 169608, Singapore.",
    "Department of Anaesthesiology, Sengkang General Hospital, 110 Sengkang E Way, Singapore, 544886, Singapore.",
    "Division of Anaesthesiology and Perioperative Medicine, Singapore General Hospital, Outram Road, Singapore, 169608, Singapore. chan.yew.weng@singhealth.com.sg.",
    "Department of Anaesthesiology, Sengkang General Hospital, 110 Sengkang E Way, Singapore, 544886, Singapore. chan.yew.weng@singhealth.com.sg."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 3,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Daryl Jian An Tan"
    },
    {
      "affs": [
        1
      ],
      "name": "Alex Chin Koon Koh"
    },
    {
      "affs": [
        2,
        3
      ],
      "name": "Yew Weng Chan"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/76k3ygaenf0tw.bib",
  "cited_by": 0,
  "doi": "10.1186/s12871-026-04209-9",
  "fulltext_url": "https://europepmc.org/articles/PMC13794710",
  "id": "76k3ygaenf0tw",
  "issns": [
    "1471-2253"
  ],
  "landing_url": "https://europepmc.org/article/MED/43073772",
  "language": "eng",
  "licence": "CC-BY-NC-ND",
  "licence_label": "CC BY-NC-ND",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc-nd/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2703|Anesthesia and Sedative Agents"
    ]
  ],
  "openalex": "W7204469972",
  "pdf_url": "https://europepmc.org/articles/PMC13794710?pdf=render",
  "pmcid": "PMC13794710",
  "pmid": "43073772",
  "published": "2026-08-27",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/76k3ygaenf0tw.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T03:20:49Z",
      "native_id": "MED:43073772",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43073772"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2703|Anesthesia and Sedative Agents",
      "subfield": "surgery"
    }
  ],
  "title": "A preliminary assessment of a novel antiviral air filter for continuous end-tidal sampling of carbon dioxide for respiratory monitoring of sedated patients: a pilot study.",
  "title_text": "A preliminary assessment of a novel antiviral air filter for continuous end-tidal sampling of carbon dioxide for respiratory monitoring of sedated patients: a pilot study.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T03:20:49Z",
  "url": "https://research.draconitic.com/paper/76k3ygaenf0tw",
  "venue": "BMC anesthesiology",
  "versions": []
}