  "abstract": "Background\n\nThe study aimed to determine what effect small changes in the set target range of an automated FiO₂ system would have on SpO₂ exposure.Methods\n\nSingle center randomized crossover design, with auto SpO₂ targets switched between 3 settings (standard, narrow and higher) every 12 h. VLBW infants needing extended respiratory support were studied. Primary outcomes were time in the intended range (88%-93% < 29 weeks PMA, otherwise 90%-95%) and time at SpO₂ extremes (≤80%, >98% with supplemental oxygen). Additional levels of SpO₂ above and below the target range were also evaluated.Results\n\nTen infants, birth weight 820 grams (IQR 673-943), were evaluated. At entry they were 14 days old (IQR 13-18) and participated for 9-30 days. Four hundred and thirty-one 12-hour epochs were evaluated. The oxygen demand was relatively low [FiO₂ 0.24 (IQR 0.22-0.30)] and oxygen saturation well controlled. They spent a median of 80% (IQR 68-87) of the time in the intended target range, with differences among the three settings not statistically significant. In contrast the % time with SpO₂ ≤ 80% during the higher setting was reduced and the % time with SpO₂ > 98% with the higher setting was increased. Narrow compared to the standard SpO₂ exposures were not different. The descriptive levels of hyperoxemia and hypoxemia were consistent with the two primary SpO₂ extremes.Conclusions\n\nNarrowing the target range had little impact, however shifting the target range up just one point had a marked impact of decreasing hypoxemia and increasing hyperoxemia.Clinical trial registration\n\nClinicalTrials.gov, identifier NCT06207994.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czechia.",
    "Neonatal Unit, Department of Obstetrics and Gynecology, Second Faculty of Medicine, Motol and Homolka University Hospital, Prague, Czechia.",
    "Department of Pathological Physiology, First Faculty of Medicine, Charles University, Prague, Czechia."
  ],
  "article_type": null,
  "arxiv": null,
  "author_total": 6,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Jana Dornakova"
    },
    {
      "affs": [
        0
      ],
      "name": "Thomas Bachman"
    },
    {
      "affs": [
        1
      ],
      "name": "Radim Brabec"
    },
    {
      "affs": [
        1
      ],
      "name": "Ekaterina Orlova"
    },
    {
      "affs": [
        1,
        2
      ],
      "name": "Jan Janota"
    },
    {
      "affs": [
        0
      ],
      "name": "Jakub Rafl"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/778h4wexdsyg4.bib",
  "cited_by": 0,
  "doi": "10.3389/fped.2026.1971581",
  "fulltext_url": "https://europepmc.org/articles/PMC13793486",
  "id": "778h4wexdsyg4",
  "issns": [
    "2296-2360"
  ],
  "landing_url": "https://europepmc.org/article/MED/43080582",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2740|Neonatal Respiratory Health Research"
    ]
  ],
  "openalex": "W7225691802",
  "pdf_url": "https://europepmc.org/articles/PMC13793486?pdf=render",
  "pmcid": "PMC13793486",
  "pmid": "43080582",
  "published": "2026-11-10",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/778h4wexdsyg4.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T03:21:06Z",
      "native_id": "MED:43080582",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43080582"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2740|Neonatal Respiratory Health Research",
      "subfield": "general"
    }
  ],
  "title": "Effect of small changes in set oxygen saturation target range during routine use of automated FiO₂ control: a randomized physiological study.",
  "title_text": "Effect of small changes in set oxygen saturation target range during routine use of automated FiO₂ control: a randomized physiological study.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:21:01Z",
  "url": "https://research.draconitic.com/paper/778h4wexdsyg4",
  "venue": "Frontiers in pediatrics",
  "versions": []
}