{
  "abstract": "Mid‑infrared Optoacoustic Spectroscopy (MiROS) has recently shown strong correlation with blood glucose in-vivo in mice, but MiROS’ long‑term performance following calibration and robustness to unseen background compositions remain unclear. We examined MiROS signal variation in relation to glucose concentrations in phantoms over periods exceeding one week, and assessed the effect of varying background constituents on glucose readings. With daily calibration, aqueous phantoms showed reproducible signals over 12 days, achieving a mean absolute error (MAE) of 9–12 mg/dL. Calibration using data from multiple prior days resulted in comparable accuracy (MAE: 12–13 mg/dL), indicating no deterioration despite increasing temporal separation between calibration and measurement. Additionally, MiROS remained robust to chemically diverse and previously unseen spectral backgrounds designed to emulate tissue variability, yielding glucose prediction errors of approximately 20 mg/dL. Collectively, these findings demonstrate the temporal stability and robustness of MiROS, supporting its further development as a platform for non-invasive glucose sensing.",
  "abstract_shown": true,
  "affiliations": [
    "Chair of Biological Imaging, Central Institute for Translational Cancer Research (TranslaTUM), School of Medicine and Health & School of Computation, Information and Technology, Technical University of Munich, Munich, Germany",
    "Institute of Biological and Medical Imaging, Bioengineering Center, Helmholtz Zentrum München, Neuherberg, Germany",
    "Munich Institute of Robotics and Machine Intelligence (MIRMI), Technical University of Munich, Munich, Germany"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 4,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Alexander Prebeck"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Aikaterini Mavroudi"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Uli Stahl"
    },
    {
      "affs": [
        0,
        1,
        2
      ],
      "name": "Vasilis Ntziachristos"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/7jjgh84nyds7y.bib",
  "cited_by": 0,
  "doi": "10.1016/j.pacs.2026.100901",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13771430/",
  "id": "7jjgh84nyds7y",
  "issns": [
    "2213-5979"
  ],
  "landing_url": "https://doi.org/10.1016/j.pacs.2026.100901",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Research Article"
    ],
    [
      "openalex",
      "1304|Spectroscopy Techniques in Biomedical and Chemical Research"
    ]
  ],
  "openalex": "W7224931094",
  "pdf_url": "https://www.sciencedirect.com/science/article/pii/S2213597926001072/pdf",
  "pmcid": "PMC13771430",
  "pmid": "43041699",
  "published": "2026-10-30",
  "publisher": "Elsevier",
  "ris": "https://research.draconitic.com/paper/7jjgh84nyds7y.ris",
  "sources": [
    {
      "first_seen": "2026-11-18T12:23:05Z",
      "native_id": "PMC13771430",
      "source": "pmc",
      "url": "https://doi.org/10.1016/j.pacs.2026.100901"
    }
  ],
  "subjects": [
    {
      "field": "biochemistry",
      "origin": "openalex:1304|Spectroscopy Techniques in Biomedical and Chemical Research",
      "subfield": "biophysics"
    }
  ],
  "title": "Longitudinal evaluation of glucose detection accuracy by spectroscopic mid-infrared optoacoustic sensing in phantoms",
  "title_text": "Longitudinal evaluation of glucose detection accuracy by spectroscopic mid-infrared optoacoustic sensing in phantoms",
  "type": "peer-reviewed",
  "updated_at": "2026-11-20T12:21:35Z",
  "url": "https://research.draconitic.com/paper/7jjgh84nyds7y",
  "venue": "Photoacoustics",
  "versions": []
}