  "abstract": "•Left atrial appendage (LAA)-Print registry analysis identified 22 retroverted LAA anatomies treated with WATCHMAN.•Retro LAA was associated with high rates of off-axis deployment, leak, and failure.•All 22 cases underwent bench testing using soft patient-specific atrial models.•Double-curve and steerable sheaths remained noncoaxial despite puncture optimization.•A newly designed retro-curve sheath restored axial alignment regardless of puncture site.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": null,
  "author_total": 9,
  "authors": [
    {
      "name": "Vlad Ciobotaru"
    },
    {
      "name": "Meyer Elbaz"
    },
    {
      "name": "Xavier Iriart"
    },
    {
      "name": "Frederic Bouisset"
    },
    {
      "name": "Guillaume Bonnet"
    },
    {
      "name": "Victor-Xavier Tadros"
    },
    {
      "name": "Emmanuel Teiger"
    },
    {
      "name": "Julien Ternacle"
    },
    {
      "name": "Sébastien Hascoët"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/7rpdyhzf75vm2.bib",
  "cited_by": 0,
  "doi": "10.1016/j.shj.2026.100820",
  "fulltext_url": null,
  "id": "7rpdyhzf75vm2",
  "issns": [
    "2474-8706"
  ],
  "landing_url": "https://hal.science/hal-05790998v1",
  "language": "en",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "journal",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "hal",
      "0.sdv"
    ],
    [
      "hal",
      "0.spi"
    ],
    [
      "openalex",
      "2705|Atrial Fibrillation Management and Outcomes"
    ]
  ],
  "openalex": "W7130568225",
  "pdf_url": null,
  "pmcid": null,
  "pmid": null,
  "published": "2026-10-10",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/7rpdyhzf75vm2.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:17:53Z",
      "native_id": "hal-05790998",
      "source": "hal",
      "url": "https://hal.science/hal-05790998v1"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2705|Atrial Fibrillation Management and Outcomes",
      "subfield": "cardiovascular"
    }
  ],
  "title": "Retro-Curve Access Sheath for Retroverted Anatomy in Left Atrial Appendage Closure: Bench Validation and Patient-Specific Simulation Study",
  "title_text": "Retro-Curve Access Sheath for Retroverted Anatomy in Left Atrial Appendage Closure: Bench Validation and Patient-Specific Simulation Study",
  "type": "peer-reviewed",
  "updated_at": "2026-10-30T12:17:53Z",
  "url": "https://research.draconitic.com/paper/7rpdyhzf75vm2",
  "venue": "Structural Heart",
  "versions": []
}