{
  "abstract": "High-dose-rate (HDR) brachytherapy is highly conformal, but its accuracy depends on catheter and source placement, and clinical workflows lack real-time in vivo dosimetry (IVD) that verifies delivery without disrupting the procedure. We characterize a scintillator-based optical dosimeter integrated into a transrectal probe that tracks source position, speed, dose rate, and time-resolved cumulative dose. A 67 mm x 5 mm line scintillator is imaged by a CMOS camera through a 30-degree endoscopic lens; geometric and flat-field corrections remove barrel distortion and vignetting. Absolute dose was calibrated with a TOPAS Monte Carlo model of the probe's air-cavity geometry. The system was validated in a water phantom with an Ir-192 source and needles at radial offsets of 7, 10, and 15 mm. Response varied by $\\pm$2\\% along the 67 mm scintillator and was linear over 5-21 cGy/s ($R^2 \\geq 0.995$). The Monte Carlo model showed a 3.75\\% dose-rate reduction relative to TG-43 water-equivalent conditions. In phantom, the system resolved a 3 mm needle displacement, confirmed by CT. Measured dose-rate profiles agreed with Monte Carlo in peak magnitude and spatial distribution, and integral dose agreed within 1\\%. By mapping dose directly to the measurement plane of a standard ultrasound transducer, this system provides high-resolution, time-resolved verification of HDR delivery and a clinical tool for detecting delivery errors with minimal changes to existing treatment protocols.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": "2611.27146",
  "author_total": 5,
  "authors": [
    {
      "name": "Kevin Willy"
    },
    {
      "name": "Megan Clark"
    },
    {
      "name": "Petr Bruza"
    },
    {
      "name": "Shauna McVorran"
    },
    {
      "name": "David Gladstone"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/83wk8d99nnc03.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2611.27146",
  "fulltext_url": null,
  "id": "83wk8d99nnc03",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2611.27146",
  "language": null,
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "http://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "physics.med-ph"
    ]
  ],
  "openalex": null,
  "pdf_url": "https://arxiv.org/pdf/2611.27146",
  "pmcid": null,
  "pmid": null,
  "published": "2026-11-20",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/83wk8d99nnc03.ris",
  "sources": [
    {
      "first_seen": "2026-11-23T07:22:25Z",
      "native_id": "2611.27146",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2611.27146"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "arxiv:physics.med-ph",
      "subfield": "biological-medical"
    }
  ],
  "title": "Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR Brachytherapy",
  "title_text": "Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR Brachytherapy",
  "type": "preprint",
  "updated_at": "2026-11-25T10:20:17Z",
  "url": "https://research.draconitic.com/paper/83wk8d99nnc03",
  "venue": "arXiv",
  "versions": []
}