{
  "abstract": "Background: Conventional phased-array torso coils used for abdominal MRI are relatively heavy and inflexible, potentially affecting patient comfort and technologist workflow.\n\nObjective: To compare image quality, patient experience, and technologist experience using a recently United States Food and Drug Administration-cleared flexible, lightweight, blanket-like torso coil versus a conventional torso coil for pediatric abdominal MRI.\n\nMaterials and methods: In this prospective institutional review board-approved study, 20 pediatric patients (7 years-old to 18 years-old) undergoing routine clinical outpatient abdominal MRI were imaged on the same 1.5-T system using both a conventional torso coil and a flexible blanket-like torso coil (Smart Fit TorsoCardiac; Philips Healthcare). After standard clinical imaging, selected sequences were repeated following coil exchange. Five pediatric radiologists independently evaluated paired image sets for subjective signal-to-noise ratio (SNR) and coil-related artifacts. Objective image quality was assessed using organ- and tissue-based SNR estimates and contrast-to-noise ratio (CNR) measurements. Patients and MRI technologists completed questionnaires regarding comfort, usability, and examination experience.\n\nResults: All 20 patients (median age, 15 years; 55% female) underwent imaging with both coils. Radiologists rated the novel coil as similar to the conventional coil for subjective SNR across all three sequences under study; coil-related artifacts were uncommon (2% of assessments for all sequences evaluated). Objective analysis showed no significant image-based SNR differences for most sequences, although the flexible coil demonstrated higher liver SNR on axial diffusion-weighted imaging (adjusted P=0.01). CNR did not differ between coils. Patients reported greater comfort and less anxiety with the flexible coil; 55% preferred it for future MRI examinations versus 20% for the conventional coil. Technologists also favored the flexible coil, with 70% expressing an overall preference.\n\nConclusion: The flexible blanket-like torso coil provided image quality similar to a conventional coil and was generally preferred by patients and MRI technologists.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Radiology, Cincinnati Children’s Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH 45229 United States",
    "Department of Radiology, University of Cincinnati, Cincinnati, United States",
    "Philips Healthcare, Best, Netherlands"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 11,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Jonathan R. Dillman",
      "orcid": "0000-0003-0124-0164"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Jean A. Tkach"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "R. Paul Guillerman"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Murat Kocaoglu",
      "orcid": "0000-0002-4674-8634"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Yinan Li"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Michael P. Nasser"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Adam F. Prasanphanich"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Amol Pednekar"
    },
    {
      "affs": [
        0
      ],
      "name": "Ashan Kharzai"
    },
    {
      "affs": [
        2
      ],
      "name": "Joshua Greer"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Jonathan A. Dudley",
      "orcid": "0000-0002-5189-9568"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/908nz6nm03e1h.bib",
  "cited_by": 0,
  "doi": "10.1007/s00247-026-06761-5",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13759554/",
  "id": "908nz6nm03e1h",
  "issns": [
    "0301-0449",
    "1432-1998"
  ],
  "landing_url": "https://doi.org/10.1007/s00247-026-06761-5",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Research"
    ],
    [
      "openalex",
      "2741|Advanced MRI Techniques and Applications"
    ]
  ],
  "openalex": "W7203978708",
  "pdf_url": "https://link.springer.com/content/pdf/10.1007/s00247-026-06761-5.pdf",
  "pmcid": "PMC13759554",
  "pmid": "42631733",
  "published": "2026-08-22",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/908nz6nm03e1h.ris",
  "sources": [
    {
      "first_seen": "2026-11-17T12:20:45Z",
      "native_id": "PMC13759554",
      "source": "pmc",
      "url": "https://doi.org/10.1007/s00247-026-06761-5"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2741|Advanced MRI Techniques and Applications",
      "subfield": "imaging"
    }
  ],
  "title": "Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T – initial experience",
  "title_text": "Evaluation of a novel flexible, lightweight blanket-like torso coil in pediatric MRI at 1.5-T – initial experience",
  "type": "peer-reviewed",
  "updated_at": "2026-11-17T12:20:45Z",
  "url": "https://research.draconitic.com/paper/908nz6nm03e1h",
  "venue": "Pediatric Radiology",
  "versions": []
}