  "abstract": "Background\n\nBreast ultrasound (BUS) is widely used for breast cancer screening, but its interpretation is operator-dependent. In computer-aided diagnosis, lesion classification and lesion segmentation are conventionally addressed by separate deep-learning models, which increases the parameter budget, computational cost, and complexity of clinical deployment. It remains unclear whether a single multi-task model can match the performance of two dedicated single-task models while reducing this overhead.Methods\n\nWe developed an attention-gated multi-task learning (MTL) framework built on a shared ResNet-34 encoder that simultaneously performs three-class classification (normal, benign, malignant) and lesion segmentation in a single forward pass. Using the publicly available BUSI dataset (780 images; stratified 70%/15%/15% train/validation/test split; fixed random seed for reproducibility), we compared the unified model against three dedicated baselines: a classification-only model, a segmentation-only model, and a segmentation-only model equipped with attention gates. Classification models were compared using the paired McNemar test, segmentation models using the paired Wilcoxon signed-rank test, and bootstrap 95% confidence intervals (1,000 resamples) were computed for the principal metrics. Model efficiency was quantified by parameter count.Results\n\nOn the held-out test set (n = 117), the unified MTL model achieved a classification accuracy of 93.16%, macro F1-score of 0.931, and macro AUC of 0.984, statistically comparable to the dedicated classification model (accuracy 91.45%; McNemar p = 0.63). Its lesion segmentation performance (mean Dice 0.766, 95% CI 0.710-0.819) was statistically comparable to the dedicated segmentation model (Dice 0.810; Wilcoxon p = 0.22). Adding attention gates to the segmentation-only baseline did not significantly change segmentation accuracy (Dice 0.813 vs. 0.810; p = 0.50). The unified model preserved clinically important behaviour, with 100% recall for normal images and no malignant case misclassified as normal. Critically, the unified model required 24.7 million parameters, compared with 45.9 million for two separate task-specific models-a 46% reduction.Conclusions\n\nA single attention-gated multi-task model can deliver breast ultrasound classification and lesion segmentation with accuracy statistically comparable to that of dedicated single-task models, while nearly halving the parameter count. These findings support the value of the unified framework for efficient, integrated computer-aided diagnosis and workflow consolidation, rather than for accuracy gains over single-task approaches.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Ultrasound, Clinical College of Chengdu Medical College, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610599, China.",
    "Department of Ultrasound, Clinical College of Chengdu Medical College, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610599, China. 102023001@cmc.edu.cn.",
    "Department of Neurosurgery, Clinical College of Chengdu Medical College, The First Affiliated Hospital of Chengdu Medical College, Chengdu, 610599, China. fanfanwind5986@163.com.",
    "Key Laboratory of Neural Injury and Repair at Chengdu Medical College of Sichuan Province, Chengdu, China. fanfanwind5986@163.com."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 5,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Yi Zhang",
      "orcid": "0000-0002-8627-2327"
    },
    {
      "affs": [
        0
      ],
      "name": "Shi-Min Liang"
    },
    {
      "affs": [
        0
      ],
      "name": "Jian Liu"
    },
    {
      "affs": [
        1
      ],
      "name": "Wen Wen"
    },
    {
      "affs": [
        2,
        3
      ],
      "name": "Ying-Jun Fan"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/9arzj3j38agdw.bib",
  "cited_by": 0,
  "doi": "10.1186/s12880-026-03007-6",
  "fulltext_url": "https://europepmc.org/articles/PMC13794363",
  "id": "9arzj3j38agdw",
  "issns": [
    "1471-2342"
  ],
  "landing_url": "https://europepmc.org/article/MED/43073782",
  "language": "eng",
  "licence": "CC-BY-NC-ND",
  "licence_label": "CC BY-NC-ND",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc-nd/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "1702|AI in cancer detection"
    ]
  ],
  "openalex": "W7225323786",
  "pdf_url": "https://europepmc.org/articles/PMC13794363?pdf=render",
  "pmcid": "PMC13794363",
  "pmid": "43073782",
  "published": "2026-11-05",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/9arzj3j38agdw.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T03:20:40Z",
      "native_id": "MED:43073782",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43073782"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "journal-openalex:2741|Radiomics and Machine Learning in Medical Imaging",
      "subfield": "imaging"
    }
  ],
  "title": "A unified attention-gated multi-task network for joint classification and lesion segmentation of breast ultrasound images.",
  "title_text": "A unified attention-gated multi-task network for joint classification and lesion segmentation of breast ultrasound images.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T03:20:40Z",
  "url": "https://research.draconitic.com/paper/9arzj3j38agdw",
  "venue": "BMC medical imaging",
  "versions": []
}