{
  "abstract": "Background\n\nPercutaneous transforaminal endoscopic discectomy (PTED) is an increasingly popular technique for treating symptomatic lumbar disc herniation (LDH) worldwide. However, performing PTED demands a high level of surgical proficiency, which can only be achieved through structured and extensive training. Current training methods remain inadequate for equipping novice surgeons.Methods\n\nBy integrating medical image reconstruction, computer-aided design (CAD), programming, and three-dimensional (3D) printing, a high-fidelity physical simulator with interactive features was developed. An exploratory cross-sectional study involving 19 neurosurgeons and trainees was conducted to examine the preliminary feasibility of the simulator for assessing PTED portal-placement performance. Participants were categorized into three subgroups based on their prior PTED experience. Each participant then performed the simulated portal placement procedure on the simulator. Performance was evaluated using a task-specific checklist, a global rating scale (GRS), and key objective metrics. Participant feedback on the training experience and the simulator itself was collected via a participant feedback survey.Results\n\nSignificant between-group differences were observed in task-specific checklist scores [F(2,16) = 32.05, P < 0.001, η² = 0.800, 95% confidence interval (CI) 0.628-0.892], GRS scores [F(2,16) = 18.30, P < 0.001, η² = 0.696, 95% CI 0.412-0.841], procedural duration [F(2,16) = 8.131, P = 0.004, η² = 0.504, 95% CI 0.150-0.726], and fluoroscopy count [F(2,16) = 5.162, P = 0.019, η² = 0.392, 95% CI 0.026-0.633]. Kruskal-Wallis sensitivity analyses supported the checklist and GRS findings. Alarm activation counts did not differ significantly among groups (H = 2.46, P = 0.293). Clinical experience was positively associated with checklist and GRS scores in exploratory Spearman analyses.Conclusion\n\nThis study presents a novel approach to developing a high-fidelity physical simulator for PTED training. The simulator distinguished participants across prior PTED experience levels in this exploratory cohort, providing preliminary evidence of its feasibility for assessing portal-placement performance. Favorable participant feedback also suggests its potential application in PTED training.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Industrial and Product Design, Sichuan Fine Arts Institute, Chongqing, China.",
    "Department of Computer Science and Artificial Intelligence, Wuhan University of Technology, Wuhan, China.",
    "Department of Digital Media Art, Sichuan Fine Arts Institute, Chongqing, China.",
    "Department of Design, Huazhong University of Science and Technology, Wuhan, China.",
    "Chongqing Medical University, Chongqing, China.",
    "Department of Orthopaedic Surgery, Chongqing Municipal Health Commission Key Laboratory of Musculoskeletal Regeneration and Translational Medicine/Orthopaedic Research Laboratory, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China. hjie2005@aliyun.com.",
    "Department of Orthopaedic Surgery, Nanchuan Hospital of Chongqing Medical University, 16 Nan Da Road, Chongqing, China. jiangwei_doc@163.com."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 10,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Bohong Cai"
    },
    {
      "affs": [
        0
      ],
      "name": "Zihan Wang"
    },
    {
      "affs": [
        0
      ],
      "name": "Xinlu Yang"
    },
    {
      "affs": [
        1
      ],
      "name": "Yiran Qiao"
    },
    {
      "affs": [
        2
      ],
      "name": "Xi Lyu"
    },
    {
      "affs": [
        3
      ],
      "name": "Yuhan Liu"
    },
    {
      "affs": [
        4
      ],
      "name": "Qi Yao"
    },
    {
      "affs": [
        4
      ],
      "name": "Baixiang Chen"
    },
    {
      "affs": [
        5
      ],
      "name": "Jie Hao"
    },
    {
      "affs": [
        6
      ],
      "name": "Wei Jiang"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/9nsn95gzqfnjc.bib",
  "cited_by": 0,
  "doi": "10.1186/s12891-026-10630-5",
  "fulltext_url": "https://europepmc.org/articles/PMC13794577",
  "id": "9nsn95gzqfnjc",
  "issns": [
    "1471-2474"
  ],
  "landing_url": "https://europepmc.org/article/MED/43079409",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2746|Surgical Simulation and Training"
    ]
  ],
  "openalex": "W7223085338",
  "pdf_url": "https://europepmc.org/articles/PMC13794577?pdf=render",
  "pmcid": "PMC13794577",
  "pmid": "43079409",
  "published": "2026-10-21",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/9nsn95gzqfnjc.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T15:21:01Z",
      "native_id": "MED:43079409",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43079409"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2746|Surgical Simulation and Training",
      "subfield": "surgery"
    }
  ],
  "title": "A high-fidelity physical simulator as a feasible assessment tool for evaluating percutaneous transforaminal endoscopic discectomy skills.",
  "title_text": "A high-fidelity physical simulator as a feasible assessment tool for evaluating percutaneous transforaminal endoscopic discectomy skills.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:21:01Z",
  "url": "https://research.draconitic.com/paper/9nsn95gzqfnjc",
  "venue": "BMC musculoskeletal disorders",
  "versions": []
}