{
  "abstract": "Background\n\nAcute calculous cholecystitis is a common surgical emergency. In health systems with delayed or limited access to radiology-performed ultrasonography, diagnostic delays may increase complications, length of stay, and resource utilization. Surgeon-performed point-of-care ultrasonography may expedite evaluation; however, its diagnostic accuracy when incorporated into structured diagnostic frameworks such as the Tokyo criteria remains uncertain.Methods\n\nWe conducted a prospective observational diagnostic accuracy study in the emergency department of a second-level referral hospital. Adult patients with clinical suspicion of acute cholecystitis were enrolled during recruitment shifts. All participants underwent standardized clinical evaluation, surgeon-performed point-of-care ultrasonography using a handheld device, and radiology-performed ultrasonography. The reference standard was pragmatic: histopathology for operated patients and structured clinical follow-up for up to 2 months for nonoperated patients. Diagnostic performance (sensitivity, specificity, likelihood ratios, predictive values, and post-test probability) was calculated for surgeon-performed ultrasonography alone, radiology-performed ultrasonography, and the Tokyo criteria using either imaging modality.Results\n\nA total of 170 patients were included (mean age 42.8 years; 78.8% women). Surgeon-performed point-of-care ultrasonography considered positive with at least 1 sonographic finding demonstrated a sensitivity of 96.4% and specificity of 55.6%, with strong rule-out capability (negative likelihood ratio 0.06; negative post-test probability approximately 1%). Radiology-performed ultrasonography showed a sensitivity of 82.1% and specificity of 64.1%. When integrated into the Tokyo criteria, surgeon-performed ultrasonography yielded a sensitivity of 78.6% and specificity of 80.3%, comparable to Tokyo criteria using radiology-performed ultrasonography, with no statistically significant difference in paired classification.Conclusions\n\nSurgeon-performed point-of-care ultrasonography demonstrated excellent sensitivity and rule-out performance. When incorporated into the Tokyo diagnostic criteria, its diagnostic performance was comparable to radiology-performed ultrasonography, supporting its use as a practical diagnostic alternative in emergency surgical settings with limited access to radiology services.",
  "abstract_shown": true,
  "affiliations": [
    "Department of General Surgery, Hospital General Regional Vicente Guerrero, Instituto Mexicano del Seguro Social (IMSS), Avenida Adolfo Ruiz Cortines s/n Acapulco De Juárez, Col. Alta Progreso, Acapulco De Juárez, 39610, Guerrero, Mexico. fco_x93@me.com.",
    "Faculty of Medicine, Benemérita Universidad Autónoma de Puebla, Puebla, Puebla, Mexico. fco_x93@me.com.",
    "Department of General Surgery, Hospital General Regional Vicente Guerrero, Instituto Mexicano del Seguro Social (IMSS), Avenida Adolfo Ruiz Cortines s/n Acapulco De Juárez, Col. Alta Progreso, Acapulco De Juárez, 39610, Guerrero, Mexico.",
    "Hospital Privado Magallanes, Acapulco, Guerrero, Mexico.",
    "Faculty of Medicine, Benemérita Universidad Autónoma de Puebla, Puebla, Puebla, Mexico."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 7,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Francisco Xavier González Servín"
    },
    {
      "affs": [
        2,
        3
      ],
      "name": "Luis Rodrigo Barrera Guerra"
    },
    {
      "affs": [
        2
      ],
      "name": "Ethel Jenny García Cruz"
    },
    {
      "affs": [
        2
      ],
      "name": "Luis Manuel Uribe Galán"
    },
    {
      "affs": [
        2,
        4
      ],
      "name": "Alberto García Rodríguez"
    },
    {
      "affs": [
        2
      ],
      "name": "Gerardo Alvarado Romero"
    },
    {
      "affs": [
        2
      ],
      "name": "Edgar Balbuena Herrera"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/b07tjrfd19krk.bib",
  "cited_by": 0,
  "doi": "10.1007/s00423-026-04154-8",
  "fulltext_url": "https://europepmc.org/articles/PMC13796562",
  "id": "b07tjrfd19krk",
  "issns": [
    "1435-2443",
    "1435-2451"
  ],
  "landing_url": "https://europepmc.org/article/MED/43077161",
  "language": "eng",
  "licence": "CC-BY-NC-ND",
  "licence_label": "CC BY-NC-ND",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc-nd/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2706|Ultrasound in Clinical Applications"
    ]
  ],
  "openalex": "W7204762695",
  "pdf_url": "https://europepmc.org/articles/PMC13796562?pdf=render",
  "pmcid": "PMC13796562",
  "pmid": "43077161",
  "published": "2026-09-01",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/b07tjrfd19krk.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T15:21:02Z",
      "native_id": "MED:43077161",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43077161"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "journal-openalex:2746|Minimally Invasive Surgical Techniques",
      "subfield": "surgery"
    }
  ],
  "title": "Diagnostic accuracy of surgeon-performed point-of-care ultrasonography using Tokyo guidelines criteria for acute cholecystitis: a prospective diagnostic accuracy study.",
  "title_text": "Diagnostic accuracy of surgeon-performed point-of-care ultrasonography using Tokyo guidelines criteria for acute cholecystitis: a prospective diagnostic accuracy study.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:21:02Z",
  "url": "https://research.draconitic.com/paper/b07tjrfd19krk",
  "venue": "Langenbeck's archives of surgery",
  "versions": []
}