  "abstract": "Translating wide-field imaging Mueller polarimetry to clinical settings requires video-rate data acquisition, achievable with polarization-sensitive division-of-focal-plane cameras. Such sensors measure only the first three rows of a sample's Mueller matrix , yielding a partial 3 × 4 Mueller matrix. Physical realizability testing of Mueller matrix is a mandatory post-processing step, which analytical implementation requires the knowledge of complete 4 × 4 Mueller matrix elements. No closed-form physical realizability test exists for partial Mueller matrices. We present a supervised machine learning framework that tests physical realizability directly on partial Mueller matrices, without the missing fourth row. Three different classifiers - XGBoost, CatBoost, and Multi-Layer Perceptron - were trained and evaluated on experimental Mueller matrix images of brain, skin and cervical tissue and also on polarized Monte Carlo simulated Mueller matrix images of optical phantoms. On independent held-out complete MM images excluded from all stages of model development, the classifiers achieve mean image-level F ₁ scores of 0.973-0.975 across the evaluated partial-MM inputs. We further show that reducing the input to the 3 × 3 top-left sub-matrix shows comparative performance, with all three classifiers generalizing comparably and the Multi-Layer Perceptron classifier offering the fastest inference.",
  "abstract_shown": true,
  "affiliations": [
    "LPICM, CNRS, Ecole polytechnique, IP Paris, 91120, Palaiseau, France.",
    "sooyong.chae@polytechnique.edu.",
    "MOE Key Laboratory of Optoelectronic Imaging Technology and System, Beijing Institute of Technology, Beijing 100081, China.",
    "Graduate School at Shenzhen Tsinghua University, Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Shenzhen, China.",
    "Department of Computer Science, ETH Zürich, 8092 Zürich, Switzerland.",
    "Support Centre for Advanced Neuroimaging, Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.",
    "Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.",
    "Department of Digital Medicine, University of Bern, 3008 Bern, Switzerland.",
    "Institute of Tissue Medicine and Pathology, University of Bern, 3008 Bern, Switzerland.",
    "Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA.",
    "tatiana.novikova@polytechnique.edu."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 12,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Sooyong Chae",
      "orcid": "0009-0007-6266-1532"
    },
    {
      "affs": [
        0,
        2
      ],
      "name": "Meishu Wang"
    },
    {
      "affs": [
        0
      ],
      "name": "Theotim Lucas"
    },
    {
      "affs": [
        0,
        3
      ],
      "name": "Tongyu Huang"
    },
    {
      "affs": [
        4,
        5
      ],
      "name": "Gianmarco Albano"
    },
    {
      "affs": [
        6
      ],
      "name": "Omar Rodriguez-Nunez",
      "orcid": "0000-0003-0280-9519"
    },
    {
      "affs": [
        0
      ],
      "name": "Angelo Pierangelo",
      "orcid": "0000-0002-7307-2537"
    },
    {
      "affs": [
        5,
        7
      ],
      "name": "Elea Gros"
    },
    {
      "affs": [
        8
      ],
      "name": "Theoni Maragkou"
    },
    {
      "affs": [
        5,
        7
      ],
      "name": "Richard McKinley"
    },
    {
      "affs": [
        6
      ],
      "name": "Philippe Schucht"
    },
    {
      "affs": [
        0,
        9,
        10
      ],
      "name": "Tatiana Novikova",
      "orcid": "0000-0002-9048-9158"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/b2ahvyhk6k2cp.bib",
  "cited_by": 0,
  "doi": "10.1364/boe.608210",
  "fulltext_url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13795929/?tool=EBI",
  "id": "b2ahvyhk6k2cp",
  "issns": [
    "2156-7085"
  ],
  "landing_url": "https://europepmc.org/article/PMC/PMC13795929",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "3107|Optical Polarization and Ellipsometry"
    ]
  ],
  "openalex": "W7213465166",
  "pdf_url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13795929/pdf/?tool=EBI",
  "pmcid": "PMC13795929",
  "pmid": "43080935",
  "published": "2026-10-14",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/b2ahvyhk6k2cp.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T03:21:04Z",
      "native_id": "PMC:PMC13795929",
      "source": "europepmc",
      "url": "https://europepmc.org/article/PMC/PMC13795929"
    },
    {
      "first_seen": "2026-11-26T15:23:43Z",
      "native_id": "MED:43080935",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43080935"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "openalex:3107|Optical Polarization and Ellipsometry",
      "subfield": "optics-photonics"
    }
  ],
  "title": "Physical realizability classification of incomplete Mueller matrices: toward real-time polarimetric imaging",
  "title_text": "Physical realizability classification of incomplete Mueller matrices: toward real-time polarimetric imaging",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:23:43Z",
  "url": "https://research.draconitic.com/paper/b2ahvyhk6k2cp",
  "venue": "Biomedical optics express",
  "versions": []
}