{
  "abstract": "For point-of-care diagnostics, the visual limit of detection (LOD) is a critical parameter directly affecting diagnostic accuracy, as clinical decisions rely heavily on naked-eye classification. Improving visual detection while maintaining operational simplicity is highly advantageous for clinical testing. Here, colorimetric lateral flow biosensors for SARS-CoV-2 nucleocapsid protein (N-protein) and Streptococcus pyogenes antigen (Strep-A) were employed as models. The effect of N-protein concentration was studied in the range of 0-300 pM. The analytical LOD, determined both by longitudinal intensity profiling with subsequent test zone peak area integration, and by fixed region-of-interest analysis, was approximately 2 pM, whereas the visual LOD was 10-15 times higher (about 20-30 pM). Similar results were obtained for Strep-A. Within this concentration gap, human visual perception fails to resolve the colorimetric signal, leading to false-negative readouts despite the analyte level exceeding the analytical LOD. We demonstrate that a streamlined workflow based on histogram equalization of sensing membrane digital images reliably resolves subvisual, true analytical signals, effectively bridging the gap between the visual and analytical LOD. By redistributing pixel intensities via a cumulative distribution function, this process amplifies subtle reflectance intensity differences that remain imperceptible to the human eye. Robustness studies confirm that this resolution enhancement remains effective across both uncompressed TIFF and compressed JPEG formats, with compressed blank controls (0 pM) remaining free from non-specific signals. Because it operates exclusively on digital records without modifying the physical sensor architecture, this accessible, data-validated strategy can be combined with chemical signal-amplification methods to achieve synergistic performance improvement effects.",
  "abstract_shown": true,
  "affiliations": [
    "Analytical/Bioanalytical & Nanotechnology Research Group, Department of Chemistry, University of Patras Rio Patras 26504 Greece christopoulou.n@ac.upatras.gr panostsikas@upatras.gr."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 3,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Natalia-Maria Christopoulou",
      "orcid": "0009-0006-5144-6143"
    },
    {
      "affs": [
        0
      ],
      "name": "Panagiotis K Tsikas",
      "orcid": "0009-0001-0481-7806"
    },
    {
      "affs": [
        0
      ],
      "name": "Theodore K Christopoulos",
      "orcid": "0000-0001-8329-884X"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/b6jmrfn87f43z.bib",
  "cited_by": 0,
  "doi": "10.1039/d6ra08921f",
  "fulltext_url": "https://europepmc.org/articles/PMC13749439",
  "id": "b6jmrfn87f43z",
  "issns": [
    "2046-2069"
  ],
  "landing_url": "https://europepmc.org/article/MED/43011389",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Chemistry"
    ],
    [
      "openalex",
      "2204|Biosensors and Analytical Detection"
    ]
  ],
  "openalex": "W7225692669",
  "pdf_url": "https://europepmc.org/articles/PMC13749439?pdf=render",
  "pmcid": "PMC13749439",
  "pmid": "43011389",
  "published": "2026-11-10",
  "publisher": "Royal Society of Chemistry",
  "ris": "https://research.draconitic.com/paper/b6jmrfn87f43z.ris",
  "sources": [
    {
      "first_seen": "2026-11-12T15:23:59Z",
      "native_id": "MED:43011389",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43011389"
    },
    {
      "first_seen": "2026-11-14T12:22:13Z",
      "native_id": "PMC13749439",
      "source": "pmc",
      "url": "https://doi.org/10.1039/d6ra08921f"
    }
  ],
  "subjects": [
    {
      "field": "chemistry",
      "origin": "heading:Chemistry",
      "subfield": "general"
    }
  ],
  "title": "Visual discrimination down to the analytical limit of detection in colorimetric lateral flow biosensors via streamlined image processing.",
  "title_text": "Visual discrimination down to the analytical limit of detection in colorimetric lateral flow biosensors via streamlined image processing.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-22T12:21:16Z",
  "url": "https://research.draconitic.com/paper/b6jmrfn87f43z",
  "venue": "RSC advances",
  "versions": []
}