  "abstract": "Background/Objectives: To evaluate, in an exploratory pilot study, the influence of slice thickness and monoenergetic (ME) level on quantitative and qualitative image quality of ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) in rectal cancer (RC). Methods: This prospective pilot study enrolled 21 patients with suspected RC undergoing pre-treatment PCD-CT between July 2023 and February 2025. All underwent a QuantumPlus portal venous phase, whose 3 mm/60 keV reconstruction served as the standard reference, plus a separate pelvic UHR acquisition. Sixteen UHR reconstructions were generated (0.6–3 mm; 45–70 keV). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and noise were analyzed using linear mixed-effects models. Three readers independently rated overall image quality, perceived noise, mesorectal fascia (MRF) sharpness and lesion conspicuity relative to the reference; ratings were analyzed using mixed model ordinal regression. The primary analysis was the within-UHR comparison of reconstruction settings; the comparison with the reference, which differed in contrast phase and acquisition parameters, was descriptive. Results: Nineteen patients (mean age 61.7 ± 10.7 years, 73.7% male) were included. CNR showed a significant slice thickness–ME level interaction (p < 0.001), ranging from 4.85 ± 2.43 (3 mm/45 keV) to 0.86 ± 1.04 (0.6 mm/70 keV). SNR increased and noise decreased with thicker slices, while both decreased with higher ME levels (all p < 0.001). ME level influenced all four qualitative parameters (all p < 0.001); slice thickness significantly affected overall quality and perceived noise (p < 0.001) but not MRF sharpness or lesion conspicuity (p ≥ 0.115). Overall quality was rated favorably in 82.9% at 70 keV versus 45.6% at 45 keV. Lesion conspicuity reached 71.9–86.0% favorable ratings, whereas perceived noise was consistently rated worse than the reference, and UHR SNR remained below the reference in all settings. In a descriptive pooled summary, 3 mm/60 keV (68.0%) and 2 mm/70 keV (66.2%) were rated favorably most often, with overlapping confidence intervals. Conclusions: Slice thickness and ME level markedly influence UHR PCD-CT image quality in RC. One candidate working reconstruction for future validation is 3 mm at 60 keV, with 2 mm at 70 keV as a plausible alternative. Because the reference differed in acquisition and contrast phase and no diagnostic endpoint was assessed, these results do not establish a diagnostic benefit of UHR PCD-CT.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Waehringer Guertel 18–20, 1090 Vienna, Austria; (A.H.); (A.S.); (D.B.); (P.S.); (T.D.); (B.N.); (F.L.); (A.B.-S.); (M.W.); (M.A.A.)",
    "Christian Doppler Laboratory for Machine Learning Driven Precision Medicine, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Waehringer Guertel 18–20, 1090 Vienna, Austria",
    "Division of Visceral Surgery, Department of General Surgery, Comprehensive Cancer Center Vienna, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria; (J.L.); (M.B.)"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 14,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Alexander Herold",
      "orcid": "0000-0002-9324-9889"
    },
    {
      "affs": [
        0,
        1
      ],
      "name": "Andreas Strassl",
      "orcid": "0000-0002-7320-0279"
    },
    {
      "affs": [
        0
      ],
      "name": "Daniela Beitzke"
    },
    {
      "affs": [
        0
      ],
      "name": "Philipp Stelzer"
    },
    {
      "affs": [
        0
      ],
      "name": "Christian Wassipaul",
      "orcid": "0000-0002-6468-5577"
    },
    {
      "affs": [
        0
      ],
      "name": "Theresa Dachs"
    },
    {
      "affs": [
        0
      ],
      "name": "Bence Nemeth"
    },
    {
      "affs": [
        0
      ],
      "name": "Florian Lindenlaub",
      "orcid": "0000-0002-0232-1639"
    },
    {
      "affs": [
        0
      ],
      "name": "Ahmed Ba-Ssalamah",
      "orcid": "0000-0002-3527-404X"
    },
    {
      "affs": [
        2
      ],
      "name": "Johannes Laengle",
      "orcid": "0000-0003-4771-1398"
    },
    {
      "affs": [
        2
      ],
      "name": "Michael Bergmann",
      "orcid": "0000-0001-8529-1166"
    },
    {
      "affs": [
        0
      ],
      "name": "Michael Weber",
      "orcid": "0000-0002-8507-2219"
    },
    {
      "affs": [
        0
      ],
      "name": "Dietmar Tamandl"
    },
    {
      "affs": [
        0
      ],
      "name": "Michael A. Arnoldner"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/bnc8b5s50z7fd.bib",
  "cited_by": 0,
  "doi": "10.3390/diagnostics16213697",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13762976/",
  "id": "bnc8b5s50z7fd",
  "issns": [
    "2075-4418"
  ],
  "landing_url": "https://doi.org/10.3390/diagnostics16213697",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Article"
    ],
    [
      "openalex",
      "2204|Advanced X-ray and CT Imaging"
    ]
  ],
  "openalex": "W7225645917",
  "pdf_url": null,
  "pmcid": "PMC13762976",
  "pmid": "43028568",
  "published": "2026-11-09",
  "publisher": "Multidisciplinary Digital Publishing Institute (MDPI)",
  "ris": "https://research.draconitic.com/paper/bnc8b5s50z7fd.ris",
  "sources": [
    {
      "first_seen": "2026-11-17T12:23:36Z",
      "native_id": "PMC13762976",
      "source": "pmc",
      "url": "https://doi.org/10.3390/diagnostics16213697"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "journal-openalex:F27",
      "subfield": "general"
    }
  ],
  "title": "Ultra-High-Resolution Imaging of Rectal Cancer with Photon-Counting Detector Computed Tomography: An Exploratory Pilot Study on the Impact of Slice Thickness and Monoenergetic Reconstruction Level on Image Quality",
  "title_text": "Ultra-High-Resolution Imaging of Rectal Cancer with Photon-Counting Detector Computed Tomography: An Exploratory Pilot Study on the Impact of Slice Thickness and Monoenergetic Reconstruction Level on Image Quality",
  "type": "peer-reviewed",
  "updated_at": "2026-11-17T12:23:36Z",
  "url": "https://research.draconitic.com/paper/bnc8b5s50z7fd",
  "venue": "Diagnostics",
  "versions": []
}