  "abstract": "High-flux electron counting with event-driven detectors is fundamentally limited by pixel-level deadtime, resulting in nonlinear count loss, variance suppression, and distortion of spatial intensity profiles. We introduce a monitor-free, self-calibrated deadtime correction method based on the invariance of the long-time Poisson tail of inter-arrival time distributions. Under stationary Poisson illumination, the long-time inter-arrival tail provides an internal statistical estimate of the incident arrival rate, independent of external flux measurements. The approach is demonstrated using high-flux transmission electron microscopy beam-profile measurements, where spatial Fano-factor analysis confirms operation in the deadtime-limited regime. By calibrating an effective extended-deadtime model with the tail-derived rate, the corrected peak count rate increases from approximately 78 kHz to 131 kHz, corresponding to a 67% increase relative to the raw peak. These results establish a self-referenced framework for deadtime correction and dynamic-range extension in event-driven electron detectors, subject to the validity of the stationary-arrival and tail-invariance assumptions.",
  "abstract_shown": true,
  "affiliations": [
    "Korea Research Institute of Standards and Science"
  ],
  "article_type": null,
  "arxiv": null,
  "author_total": 3,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Joohyun Lee"
    },
    {
      "affs": [
        0
      ],
      "name": "Ji-Hwan Kwon"
    },
    {
      "affs": [
        0
      ],
      "name": "Sooheyong Lee"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/bnt56zzphqgcm.bib",
  "cited_by": 0,
  "doi": "10.1186/s40543-026-00574-9",
  "fulltext_url": "https://doi.org/10.1186/s40543-026-00574-9",
  "id": "bnt56zzphqgcm",
  "issns": [
    "2093-3371"
  ],
  "landing_url": "https://doi.org/10.1186/s40543-026-00574-9",
  "language": "en",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "journal",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "lcc",
      "QD1-999"
    ],
    [
      "lcc",
      "QD71-142"
    ],
    [
      "openalex",
      "2508|Electron and X-Ray Spectroscopy Techniques"
    ]
  ],
  "openalex": "W7223174243",
  "pdf_url": "https://link.springer.com/content/pdf/10.1186/s40543-026-00574-9.pdf",
  "pmcid": null,
  "pmid": null,
  "published": "2026-10-25",
  "publisher": "SpringerOpen",
  "ris": "https://research.draconitic.com/paper/bnt56zzphqgcm.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T13:46:06Z",
      "native_id": "e80106bb0364466b92b1164920ccac56",
      "source": "doaj",
      "url": "https://doi.org/10.1186/s40543-026-00574-9"
    }
  ],
  "subjects": [
    {
      "field": "chemistry",
      "origin": "openalex:2508|Electron and X-Ray Spectroscopy Techniques",
      "subfield": "materials-polymers"
    }
  ],
  "title": "Self-calibrated deadtime correction using poisson-tail invariance in event-driven electron detectors",
  "title_text": "Self-calibrated deadtime correction using poisson-tail invariance in event-driven electron detectors",
  "type": "peer-reviewed",
  "updated_at": "2026-10-30T13:46:06Z",
  "url": "https://research.draconitic.com/paper/bnt56zzphqgcm",
  "venue": "Journal of Analytical Science and Technology",
  "versions": []
}