  "abstract": "Background Hand microvasculature is conventionally presented through diagrams, cadaveric atlases and specialized optical instruments, while conventional clinical radiography cannot resolve individual capillary loops (5-15 m lumen) in vivo, which dominate cutaneous oxygen exchange. Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module. The single-file application runs offline on a laptop or, over local HTTPS, on a phone as an installable app. Results Its 3D atlas contains 136 named structures per hand in six systems from open Z-Anatomy/BodyParts3D meshes, plus a literature-parameterized capillary layer. The NVC module renders a 200x, 1.2-mm field with six deterministic patterns and quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. A lumped model reports nine estimates (SIM); a physics module shows that a 10-m capillary occupies 0.07 of a 150-m detector pixel; with iodinated contrast it retains {approx}0.016% effective contrast, about 60x below a 1% detection threshold; unenhanced blood is {approx}270x lower. The 2D stage renders in 2.9 ms per frame; system merging reduces atlas draw calls from 136 to 6. Conclusions The camera-overlay layers are templates, the atlas macro-anatomy is open mesh data, and the capillary layer is sampled. No patient data are used. The instrument is a product prototype, not a medical device, and provides a reproducible framework for making multi-scale microvascular reasoning visible.",
  "abstract_shown": true,
  "affiliations": [
    "Chinese Academy of Medical Sciences & Peking Union Medical College"
  ],
  "article_type": "PUBLISHAHEADOFPRINT",
  "arxiv": null,
  "author_total": 8,
  "authors": [
    {
      "name": "Y. Wang"
    },
    {
      "name": "J. He"
    },
    {
      "affs": [
        0
      ],
      "name": "W. Liu"
    },
    {
      "name": "X. Xu"
    },
    {
      "name": "B. Li"
    },
    {
      "name": "Y. Li"
    },
    {
      "name": "B. Wang"
    },
    {
      "affs": [
        0
      ],
      "name": "M. Liu"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/bvnxebj8v1w7k.bib",
  "cited_by": 0,
  "doi": "10.64898/2026.11.15.26368085",
  "fulltext_url": "https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1.full",
  "id": "bvnxebj8v1w7k",
  "issns": [],
  "landing_url": "https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1",
  "language": null,
  "licence": "CC-BY-NC",
  "licence_label": "CC BY-NC",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "medrxiv",
      "health informatics"
    ]
  ],
  "openalex": null,
  "pdf_url": "https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1.full.pdf",
  "pmcid": null,
  "pmid": null,
  "published": "2026-11-15",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/bvnxebj8v1w7k.ris",
  "sources": [
    {
      "first_seen": "2026-11-18T00:20:51Z",
      "native_id": "10.64898/2026.11.15.26368085",
      "source": "medrxiv",
      "url": "https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "medrxiv:health informatics",
      "subfield": "epidemiology-public-health"
    }
  ],
  "title": "Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy",
  "title_text": "Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy",
  "type": "preprint",
  "updated_at": "2026-11-19T00:20:18Z",
  "url": "https://research.draconitic.com/paper/bvnxebj8v1w7k",
  "venue": "medRxiv",
  "versions": []
}