{
  "abstract": "Real-time dosimetry of ultra-high-dose-rate (UHDR) pulsed X-rays remains a major challenge. This proof-of-principle study investigates a dosimetry method for UHDR pulsed X-rays based on radiation-induced acoustic (RA) signals from a thin metal foil. The foil combines efficient X-ray absorption and acoustic resonance, converting deposited dose into acoustic signals with discrete resonant frequencies. Single-pulse measurements were performed at six dose levels spanning approximately 1--40 mGy(Si), with one pulse recorded at each level and instantaneous dose rates reaching the order of 10^6 Gy/s at the highest dose settings. The peak-to-peak amplified transducer-output voltage exhibited a linear relationship with the reference dose measured by thermoluminescent dosimeters (TLDs). These results demonstrate the feasibility of single-pulse acoustic dosimetry under the tested conditions. Furthermore, we establish analytical solutions for radiation-induced acoustic signals in a one-dimensional layered medium in both the time and frequency domains, providing a theoretical basis for signal interpretation and detector optimization.",
  "abstract_shown": true,
  "affiliations": [],
  "article_type": null,
  "arxiv": "2611.27772",
  "author_total": 10,
  "authors": [
    {
      "name": "Qihang Han"
    },
    {
      "name": "Ke Chen"
    },
    {
      "name": "Chenghao Hua"
    },
    {
      "name": "Haoran Chen"
    },
    {
      "name": "Lili Ding"
    },
    {
      "name": "Changhui Li"
    },
    {
      "name": "Xiaoping Ouyang"
    },
    {
      "name": "Chenhui Wang"
    },
    {
      "name": "Wei Chen"
    },
    {
      "name": "Wenjun Ma"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/cz2h63jqmrdwf.bib",
  "cited_by": 0,
  "doi": "10.48550/arxiv.2611.27772",
  "fulltext_url": null,
  "id": "cz2h63jqmrdwf",
  "issns": [],
  "landing_url": "https://arxiv.org/abs/2611.27772",
  "language": null,
  "licence": "LicenseRef-arXiv-nonexclusive-1.0",
  "licence_label": "arXiv licence",
  "licence_source": "article",
  "licence_url": "http://arxiv.org/licenses/nonexclusive-distrib/1.0/",
  "metadata_licence": "CC0-1.0",
  "native_subjects": [
    [
      "arxiv",
      "physics.acc-ph"
    ],
    [
      "arxiv",
      "physics.ins-det"
    ]
  ],
  "openalex": null,
  "pdf_url": "https://arxiv.org/pdf/2611.27772",
  "pmcid": null,
  "pmid": null,
  "published": "2026-11-20",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/cz2h63jqmrdwf.ris",
  "sources": [
    {
      "first_seen": "2026-11-23T07:22:25Z",
      "native_id": "2611.27772",
      "source": "arxiv",
      "url": "https://arxiv.org/abs/2611.27772"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "arxiv:physics.acc-ph",
      "subfield": "applied-instrumentation"
    }
  ],
  "title": "Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals",
  "title_text": "Single-Pulse Dosimetry for Ultra-High-Dose-Rate X-Ray Pulses Based on Radiation-Induced Acoustic Signals",
  "type": "preprint",
  "updated_at": "2026-11-25T10:20:17Z",
  "url": "https://research.draconitic.com/paper/cz2h63jqmrdwf",
  "venue": "arXiv",
  "versions": []
}