{
  "abstract": "Background: Consensus‐recommended follow‐up after cardiac implantable electronic device (CIED) implantation improves outcomes, yet whether it mediates cardiovascular disparities between device types remains unknown.\n\nMethods: We prospectively studied 6806 patients undergoing CIED implantation across a multi‐hospital system (2019–2023; median follow‐up 3.5 years), categorized as implantable cardioverter defibrillator (ICD) (n = 2757) or permanent pacemaker (PPM) (n = 4049). Causal mediation analysis decomposed the effect of device type on major adverse cardiovascular events (MACE) and device extraction into direct and follow‐up mediated components, adjusting for demographics and comorbidities.\n\nResults: ICD recipients had significantly lower consensus‐recommended follow‐up rates than PPM recipients (65.3% vs. 79.2%; adjusted OR 0.46, 95% CI 0.40–0.52, p < 0.001) and substantially higher MACE risk (HR 1.89, 95% CI 1.66–2.25, p < 0.001), of which 53.5% was mediated by follow‐up adherence. Device extraction rates were lower in ICD recipients (HR 0.30, 95% CI 0.24–0.38), with only 7.9% mediated by follow‐up adherence.\n\nConclusions: More than half of the excess cardiovascular risk in ICD recipients was statistically mediated by suboptimal follow‐up adherence—a potentially modifiable pathway. These findings identify follow‐up adherence as a potentially important pathway and support further prospective investigation of strategies to improve monitoring and clinical outcomes in high‐risk CIED populations.",
  "abstract_shown": true,
  "affiliations": [
    "Section of Cardiac Electrophysiology, Department of Medicine Emory University School of Medicine Atlanta Georgia USA",
    "Department of Epidemiology Emory University Rollins School of Public Health Atlanta Georgia USA"
  ],
  "article_type": "brief report",
  "arxiv": null,
  "author_total": 4,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Jingwen Huang",
      "orcid": "0000-0002-8583-7381"
    },
    {
      "affs": [
        0
      ],
      "name": "Rahul Patel"
    },
    {
      "affs": [
        1
      ],
      "name": "Chang Liu",
      "orcid": "0000-0002-8918-7224"
    },
    {
      "affs": [
        0
      ],
      "name": "Michael S. Lloyd",
      "orcid": "0000-0002-0708-9330"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/dtrg7xetzhyf2.bib",
  "cited_by": 0,
  "doi": "10.1111/jce.70521",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13768773/",
  "id": "dtrg7xetzhyf2",
  "issns": [
    "1045-3873",
    "1540-8167"
  ],
  "landing_url": "https://doi.org/10.1111/jce.70521",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Brief Communication"
    ],
    [
      "openalex",
      "2705|Cardiac pacing and defibrillation studies"
    ]
  ],
  "openalex": "W7220728234",
  "pdf_url": "https://onlinelibrary.wiley.com/doi/pdfdirect/10.1111/jce.70521",
  "pmcid": "PMC13768773",
  "pmid": "42836737",
  "published": "2026-10-06",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/dtrg7xetzhyf2.ris",
  "sources": [
    {
      "first_seen": "2026-11-18T12:20:39Z",
      "native_id": "PMC13768773",
      "source": "pmc",
      "url": "https://doi.org/10.1111/jce.70521"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2705|Cardiac pacing and defibrillation studies",
      "subfield": "cardiovascular"
    }
  ],
  "title": "Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients",
  "title_text": "Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients",
  "type": "peer-reviewed",
  "updated_at": "2026-11-18T12:20:39Z",
  "url": "https://research.draconitic.com/paper/dtrg7xetzhyf2",
  "venue": "Journal of Cardiovascular Electrophysiology",
  "versions": []
}