  "abstract": "Traditional indoor environmental quality standards rely on static regional climate averages, leaving built infrastructure vulnerable to extreme weather volatility and grid breakdown. This paper proposes a novel biomimetic building envelope that enforces an absolute biological baseline of 18–22°C (40–50% RH) for human cognitive and autonomic optimal performance. Mimicking human dermal microvasculature, the system integrates 3D-printed microfluidic hydronic networks (0.5–2.0 mm channels) within thermal envelopes, governed by thermo-responsive shape-memory polymers and predictive AI motion-tracking algorithms. During grid outage scenarios under 42°C extreme summer heat, the autonomous system maintains the 18–22°C refuge zone using localized radiant heat exchange and controlled standby drift (16–17°C winter / 24–25°C summer), reducing exergy consumption by 42.6% compared to VRF systems and eliminating thermal shock. Financial analysis demonstrates that despite a 7.4% initial CAPEX increase, the system achieves full payback within 3.8 years through OPEX reduction and human capital productivity retention under the 3-30-300 rule.",
  "abstract_shown": true,
  "affiliations": [
    "Mola Mola Lab White Studio"
  ],
  "article_type": null,
  "arxiv": null,
  "author_total": 1,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Jinseong Min",
      "orcid": "0009-0002-7589-8081"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/e1kac6dxynd02.bib",
  "cited_by": 0,
  "doi": "10.5281/zenodo.23419325",
  "fulltext_url": null,
  "id": "e1kac6dxynd02",
  "issns": [],
  "landing_url": "https://zenodo.org/records/23419325",
  "language": "eng",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [],
  "openalex": null,
  "pdf_url": "https://zenodo.org/api/records/23419325/files/Microvascular%20Building%20Envelopes_%20Autonomous%20Thermo-Responsive%20Fluidics%20and%20Predictive%20Setback%20Buffering%20for%20Off-Grid%20Thermal%20Resilience%20During%20Extreme%20Climate%20Volatility.pdf/content",
  "pmcid": null,
  "pmid": null,
  "published": "2026-10-16",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/e1kac6dxynd02.ris",
  "sources": [
    {
      "first_seen": "2026-10-30T12:17:42Z",
      "native_id": "23419325",
      "source": "zenodo",
      "url": "https://zenodo.org/records/23419325"
    }
  ],
  "subjects": [],
  "title": "Microvascular Building Envelopes: Autonomous Thermo-Responsive Fluidics and Predictive Setback Buffering for Off-Grid Thermal Resilience During Extreme Climate Volatility",
  "title_text": "Microvascular Building Envelopes: Autonomous Thermo-Responsive Fluidics and Predictive Setback Buffering for Off-Grid Thermal Resilience During Extreme Climate Volatility",
  "type": "preprint",
  "updated_at": "2026-10-30T12:33:40Z",
  "url": "https://research.draconitic.com/paper/e1kac6dxynd02",
  "venue": "Zenodo",
  "versions": []
}