{
  "abstract": "Background: Surgeon-specific surgically induced astigmatism (SIA) is commonly considered in toric intraocular lens (IOL) calculations; however, a mean SIA vector does not indicate whether the underlying surgical effect is reproducible across cases. Methods: We developed a quantitative framework based on axial circular statistics to characterize SIA reproducibility. Directional consistency was assessed using the mean resultant length (R), while a magnitude-weighted extension (Rw) quantified whether the astigmatic power was concentrated around a predominant direction. Variability in scalar SIA magnitude was independently assessed using the coefficient of variation (CV). Theoretically derived operational thresholds were established from geometric and relative-dispersion criteria and integrated into a decision framework. A controlled synthetic simulation using Barrett Toric calculations compared higher- and lower-consistency SIA distributions across 20 matched ocular profiles at each of two centroid magnitudes, estimating final theoretical residual astigmatism under a common-plane approximation. Results: R and Rw provide complementary normalized measures of directional reproducibility, whereas CV captures variability in SIA magnitude. A threshold of 0.70 for R and Rw was geometrically derived from 1/2, corresponding to a symmetric ±22.5° deviation around the predominant clinical astigmatic axis. CV thresholds of <20%, 20–50%, and >50% were proposed to represent low, intermediate, and high relative magnitude variability, respectively. Higher SIA consistency yielded lower mean final theoretical residual astigmatism at both centroid magnitudes: 0.25 versus 0.51 D for the 0.26 D centroid and 0.42 versus 0.90 D for the 0.55 D centroid. Conclusions: Combined assessment of R, Rw, and CV provides a quantitative framework for determining whether a mean SIA adequately represents its underlying vector distribution before incorporation into toric IOL calculators. These theoretically derived thresholds require subsequent clinical validation.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Glaucoma and Neuro-Ophthalmology, Hospital Arruzafa, 14012 Cordoba, Spain",
    "Department of Information Technology, Hospital Arruzafa, 14012 Cordoba, Spain",
    "Department of Condensed Matter Physics, Optics Area, Faculty of Pharmacy, University of Seville, 41012 Seville, Spain",
    "Department of Optometry, Hospital Arruzafa, 14012 Cordoba, Spain"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 4,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Teresa Laborda-Guirao"
    },
    {
      "affs": [
        1
      ],
      "name": "Christian Hierro-Cordón"
    },
    {
      "affs": [
        2
      ],
      "name": "José María Sánchez-González",
      "orcid": "0000-0003-0450-7717"
    },
    {
      "affs": [
        3
      ],
      "name": "Timoteo González-Cruces",
      "orcid": "0000-0001-9594-1601"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/ehy2ayg5ab5mr.bib",
  "cited_by": 0,
  "doi": "10.3390/jcm15228999",
  "fulltext_url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13804703/?tool=EBI",
  "id": "ehy2ayg5ab5mr",
  "issns": [
    "2077-0383"
  ],
  "landing_url": "https://www.mdpi.com/2077-0383/15/22/8999",
  "language": "eng",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [],
  "openalex": null,
  "pdf_url": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13804703/pdf/?tool=EBI",
  "pmcid": "PMC13804703",
  "pmid": null,
  "published": "2026-11-01",
  "publisher": "MDPI AG",
  "ris": "https://research.draconitic.com/paper/ehy2ayg5ab5mr.ris",
  "sources": [
    {
      "first_seen": "2026-11-19T00:21:27Z",
      "native_id": "10.3390/jcm15228999",
      "source": "crossref",
      "url": "https://www.mdpi.com/2077-0383/15/22/8999"
    },
    {
      "first_seen": "2026-11-26T15:21:47Z",
      "native_id": "PMC:PMC13804703",
      "source": "europepmc",
      "url": "https://europepmc.org/article/PMC/PMC13804703"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "journal-openalex:F27",
      "subfield": "general"
    }
  ],
  "title": "Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation",
  "title_text": "Beyond Mean Surgically Induced Astigmatism: A Directional Reproducibility Framework for Toric IOL Calculation",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:21:47Z",
  "url": "https://research.draconitic.com/paper/ehy2ayg5ab5mr",
  "venue": "Journal of Clinical Medicine",
  "versions": []
}