  "abstract": "In this study, intra-fraction motion management using gating and baseline shift corrections on a 1.5 T magnetic resonance linear accelerator was evaluated in 93 prostate cancer patients. Motion tracks were analyzed to assess the frequency, size and duration of baseline shift corrections and derive planning target volume (PTV) margins. Baseline shift corrections were required in 89.2% of patients, with a range of 0–6 corrections per fraction. The resulting PTV margins were 1.2 mm left-right, and 2.3 mm anterior-posterior and cranial-caudal. Because these values were conservatively estimated, a 2 mm isotropic PTV margin was clinically implemented without increasing treatment time.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Radiation Oncology, Division of Imaging & Oncology, University Medical Center Utrecht, Utrecht, the Netherlands",
    "Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, the Netherlands"
  ],
  "article_type": "brief report",
  "arxiv": null,
  "author_total": 5,
  "authors": [
    {
      "affs": [
        0,
        1
      ],
      "name": "Nienke D. Sijtsema"
    },
    {
      "affs": [
        0
      ],
      "name": "Guus Grimbergen"
    },
    {
      "affs": [
        0
      ],
      "name": "Eline N. de Groot-van Breugel"
    },
    {
      "affs": [
        0
      ],
      "name": "Jochem R.N. van der Voort van Zyp"
    },
    {
      "affs": [
        0
      ],
      "name": "Johannes C.J. de Boer"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/ekzepesj0z8mv.bib",
  "cited_by": 0,
  "doi": "10.1016/j.phro.2026.101127",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13786217/",
  "id": "ekzepesj0z8mv",
  "issns": [
    "2405-6316"
  ],
  "landing_url": "https://doi.org/10.1016/j.phro.2026.101127",
  "language": "en",
  "licence": "CC-BY-4.0",
  "licence_label": "CC BY 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Short Communication"
    ],
    [
      "openalex",
      "3108|Advanced Radiotherapy Techniques"
    ]
  ],
  "openalex": "W7225799851",
  "pdf_url": "https://www.phiro.science/article/S2405-6316(26)00227-7/pdf",
  "pmcid": "PMC13786217",
  "pmid": "43066152",
  "published": "2026-11-11",
  "publisher": "Elsevier",
  "ris": "https://research.draconitic.com/paper/ekzepesj0z8mv.ris",
  "sources": [
    {
      "first_seen": "2026-11-24T12:21:19Z",
      "native_id": "PMC13786217",
      "source": "pmc",
      "url": "https://doi.org/10.1016/j.phro.2026.101127"
    }
  ],
  "subjects": [
    {
      "field": "physics",
      "origin": "openalex:3108|Advanced Radiotherapy Techniques",
      "subfield": "applied-instrumentation"
    }
  ],
  "title": "Influence of gating and drift correction on prostate cancer treatment margins on a 1.5 T magnetic resonance linear accelerator☆",
  "title_text": "Influence of gating and drift correction on prostate cancer treatment margins on a 1.5 T magnetic resonance linear accelerator☆",
  "type": "peer-reviewed",
  "updated_at": "2026-11-24T12:21:19Z",
  "url": "https://research.draconitic.com/paper/ekzepesj0z8mv",
  "venue": "Physics and Imaging in Radiation Oncology",
  "versions": []
}