{
  "abstract": "Purpose\n\nTo test whether the residual between ray-traced total corneal astigmatism and the vector sum of the anterior and posterior second-order astigmatic components is an independent, disease-related signal or a proportionally conserved feature of corneal thick-lens optics.Methods\n\nSecondary analysis of a deidentified multicenter database of unoperated eyes examined with Pentacam HR and Corvis ST, restricted to clinically normal eyes and bilateral keratoconus, one eye per subject (1,680 normal; 1,181 keratoconic). Second-order Zernike astigmatic vectors were extracted over a 6.0 mm zone for the anterior (F) and posterior (B) surfaces and the ray-traced total cornea (T). The primary endpoint was the non-summation magnitude |T-F-B|. Pre-specified secondary analyses normalized the residual to total and anterior astigmatism, examined meridional-axis behavior, and tested associations with dynamic corneal response and composite indices. A sensitivity analysis added very asymmetric ectasia eyes.Results\n\nAbsolute non-summation was greater in keratoconic than in normal eyes (median 0.223 vs 0.155 µm; P < 0.001; Cliff's δ = 0.225, a small effect), but every astigmatic magnitude was scaled by a similar factor (anterior ×1.48, posterior ×1.28, total ×1.52, non-summation ×1.43). Within each group the residual was near-collinear with anterior astigmatism (Spearman ρ = 0.99), and its normalized fraction was essentially identical in normal and keratoconic eyes (median 0.149 vs. 0.147; Cliff's δ = -0.06) and in both eyes of patients with very asymmetric ectasia (0.147-0.149). Front-back meridional misalignment did not differ (5.89° vs. 5.63°; P = 0.49). Partial correlations with dynamic corneal response and composite indices, adjusted for astigmatism magnitude, were uniformly weak (|ρ| < 0.11).Conclusions\n\nCorneal astigmatism is not fully described by vector summation of the two surfaces. The residual, compatible with thick-lens coupling and device-specific optical conventions, is larger in absolute terms in keratoconus but represents a constant proportion of each eye's astigmatism across the ectatic spectrum. We interpret it as a magnitude-coupled optical descriptor, not an independent diagnostic or biomechanical signal. Clinically, these findings caution against assuming direct additivity of the exported anterior and posterior astigmatic components; implications for toric and refractive planning require validation against clinically relevant optical outputs and postoperative outcomes. Future studies should model corneal and tear-film refractive-index effects explicitly.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Ophthalmology and Corneal/Refractive Surgery, Eye Institute, Parauapebas, Pará, Brazil.",
    "NewVision Clinics, Melbourne, VIC, Australia.",
    "TECLens, LLC, Stamford, CT, United States.",
    "Computing Institute, Federal University of Alagoas (UFAL), Maceió, Brazil.",
    "Department of Ophthalmology, Federal University of São Paulo (UNIFESP), São Paulo, Brazil.",
    "Brazilian Artificial Intelligence Network in Medicine (BrAIN), Rio de Janeiro, Brazil.",
    "Ophthalmology Department, Alder Hey Children's NHS Foundation Trust, Liverpool, United Kingdom.",
    "Department of Ophthalmology, Federal University of the State of Rio de Janeiro (UNIRIO), Rio de Janeiro, Brazil."
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 9,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Miguel Braga-Reis"
    },
    {
      "affs": [
        1
      ],
      "name": "Noel A Alpins"
    },
    {
      "affs": [
        1
      ],
      "name": "James K Y Ong"
    },
    {
      "affs": [
        2
      ],
      "name": "Ibrahim Seven"
    },
    {
      "affs": [
        2
      ],
      "name": "Patrick Lopath"
    },
    {
      "affs": [
        3,
        4,
        5
      ],
      "name": "Aydano P Machado"
    },
    {
      "affs": [
        5,
        6
      ],
      "name": "Bernardo T Lopes"
    },
    {
      "affs": [
        4,
        5
      ],
      "name": "Karolyna Carvalho"
    },
    {
      "affs": [
        4,
        5,
        7
      ],
      "name": "Renato Ambrósio"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/f95m3ehkx76rg.bib",
  "cited_by": 0,
  "doi": "10.3389/fmed.2026.1935822",
  "fulltext_url": "https://europepmc.org/articles/PMC13793067",
  "id": "f95m3ehkx76rg",
  "issns": [
    "2296-858X"
  ],
  "landing_url": "https://europepmc.org/article/MED/43080410",
  "language": "eng",
  "licence": "CC-BY",
  "licence_label": "CC BY",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "openalex",
      "2731|Corneal surgery and disorders"
    ]
  ],
  "openalex": "W7225742480",
  "pdf_url": "https://europepmc.org/articles/PMC13793067?pdf=render",
  "pmcid": "PMC13793067",
  "pmid": "43080410",
  "published": "2026-11-10",
  "publisher": null,
  "ris": "https://research.draconitic.com/paper/f95m3ehkx76rg.ris",
  "sources": [
    {
      "first_seen": "2026-11-26T03:21:06Z",
      "native_id": "MED:43080410",
      "source": "europepmc",
      "url": "https://europepmc.org/article/MED/43080410"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "openalex:2731|Corneal surgery and disorders",
      "subfield": "general"
    }
  ],
  "title": "Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.",
  "title_text": "Proportional conservation of vectorial non-summation in corneal astigmatism: a thick-lens analysis in normal and keratoconic eyes.",
  "type": "peer-reviewed",
  "updated_at": "2026-11-26T15:21:01Z",
  "url": "https://research.draconitic.com/paper/f95m3ehkx76rg",
  "venue": "Frontiers in medicine",
  "versions": []
}