  "abstract": "Background: Lung Imaging Reporting and Data System (Lung-RADS) 4 pulmonary nodules require further evaluation because of indeterminate malignancy risk. However, repeated computed tomography (CT) examinations raise concerns about cumulative radiation exposure, and ultrashort echo time magnetic resonance imaging (UTE-MRI) remains limited by spatial resolution and motion sensitivity. This study aimed to assess the diagnostic performance of generative adversarial network (GAN)-based super-resolution UTE MRI (SR-UTE-MRI) in combination with star-volumetric interpolated breath hold examination (Star-VIBE) dynamic contrast-enhanced MRI (DCE-MRI) for such nodules, using CT and histopathological findings as reference standards.\n\nMethods: In this prospective study, patients with Lung-RADS 4 pulmonary nodules underwent CT, free-breathing UTE-MRI with subsequent SR reconstruction, and Star-VIBE DCE-MRI. Nodule size, morphological features, and perfusion parameters were assessed. Diagnostic performance of individual imaging metrics and a combined model was evaluated using receiver operating characteristic (ROC) curve analysis. A total of 91 patients (43 men and 48 women; mean age, 56.2±13.9 years) with 91 nodules (27 part-solid and 64 solid; mean diameter, 24.1±8.9 mm) were finally included.\n\nResults: Measurements derived from UTE-MRI underestimated mean nodule diameter relative to CT, resulting in misclassification in a subset of nodules. SR-UTE-MRI images reduced measurement bias and improved Lung-RADS classification accuracy and visualization of morphological features. Malignant pulmonary nodules demonstrated significantly higher volume transfer constant (Ktrans) and rate constant (Kep) values compared with benign nodules (Ktrans: 0.28 ± 0.19 min−1 vs. 0.16±0.11 min−1, P<0.001; Kep: 0.79±0.38 min−1 vs. 0.53±0.23 min−1,P<0.001). Among individual parameters, Ktrans exhibited the highest diagnostic performance [area under the curve (AUC) =0.799; cut-off, 0.14 min−1]. A multiparametric model incorporating perfusion parameters, nodule size, and spiculation yielded superior discriminatory performance (AUC =0.946; sensitivity =91%; specificity =88%; accuracy =90%).\n\nConclusions: GAN-based SR-UTE reduced the underestimation of lesion size associated with UTE-MRI and improved the accuracy of Lung-RADS classification. Star-VIBE DCE-MRI provided quantitative functional biomarkers for the assessment of malignancy. The integration of structural and functional imaging parameters yielded superior diagnostic performance compared with single-modality or single-parameter approaches, highlighting its potential as a comprehensive, non-ionizing imaging strategy for evaluation of indeterminate pulmonary nodules.",
  "abstract_shown": true,
  "affiliations": [
    "Department of Radiology, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China"
  ],
  "article_type": "research article",
  "arxiv": null,
  "author_total": 8,
  "authors": [
    {
      "affs": [
        0
      ],
      "name": "Hui Liu"
    },
    {
      "affs": [
        0
      ],
      "name": "Meng-Ting Duan"
    },
    {
      "affs": [
        0
      ],
      "name": "Ning Zhang"
    },
    {
      "affs": [
        0
      ],
      "name": "Li-Jia Wang"
    },
    {
      "affs": [
        0
      ],
      "name": "Xiao-Jia Cai"
    },
    {
      "affs": [
        0
      ],
      "name": "Si-Xue Xie"
    },
    {
      "affs": [
        0
      ],
      "name": "Gao-Feng Shi"
    },
    {
      "affs": [
        0
      ],
      "name": "Hui Feng"
    }
  ],
  "bibtex": "https://research.draconitic.com/paper/fxtcg3cj8eyd6.bib",
  "cited_by": 0,
  "doi": "10.21037/qims-2026-1365",
  "fulltext_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13743324/",
  "id": "fxtcg3cj8eyd6",
  "issns": [
    "2223-4292",
    "2223-4306"
  ],
  "landing_url": "https://doi.org/10.21037/qims-2026-1365",
  "language": "en",
  "licence": "CC-BY-NC-ND-4.0",
  "licence_label": "CC BY-NC-ND 4.0",
  "licence_source": "article",
  "licence_url": "https://creativecommons.org/licenses/by-nc-nd/4.0/",
  "metadata_licence": null,
  "native_subjects": [
    [
      "heading",
      "Original Article"
    ],
    [
      "openalex",
      "2740|Lung Cancer Diagnosis and Treatment"
    ]
  ],
  "openalex": "W7223230991",
  "pdf_url": null,
  "pmcid": "PMC13743324",
  "pmid": "42997947",
  "published": "2026-10-20",
  "publisher": "AME Publications",
  "ris": "https://research.draconitic.com/paper/fxtcg3cj8eyd6.ris",
  "sources": [
    {
      "first_seen": "2026-11-10T12:24:00Z",
      "native_id": "PMC13743324",
      "source": "pmc",
      "url": "https://doi.org/10.21037/qims-2026-1365"
    }
  ],
  "subjects": [
    {
      "field": "medicine",
      "origin": "journal-openalex:2741|Advanced MRI Techniques and Applications",
      "subfield": "imaging"
    }
  ],
  "title": "Deep learning-based super-resolution ultrashort echo time MRI combined with free-breathing Star-VIBE dynamic contrast-enhanced MRI for characterization of Lung-RADS 4 pulmonary nodules",
  "title_text": "Deep learning-based super-resolution ultrashort echo time MRI combined with free-breathing Star-VIBE dynamic contrast-enhanced MRI for characterization of Lung-RADS 4 pulmonary nodules",
  "type": "peer-reviewed",
  "updated_at": "2026-11-10T12:24:00Z",
  "url": "https://research.draconitic.com/paper/fxtcg3cj8eyd6",
  "venue": "Quantitative Imaging in Medicine and Surgery",
  "versions": []
}