BackgroundPercutaneous mechanical circulatory support (pMCS) is increasingly used in critically ill patients, yet its value in relation to cost and outcomes remains unclear. We evaluated national variation in utilization, outcomes, and cost, and introduced a value-of-care framework integrating risk-adjusted outcomes and expenditures.

MethodsWe performed a retrospective cohort study using the National Inpatient Sample to identify non-elective hospitalizations of critically ill patients undergoing intra-aortic balloon pump (IABP) or percutaneous left ventricular assist device (pLVAD) placement using ICD-10 codes. Multivariable logistic regression and generalized linear models were used to estimate expected outcomes and costs. Observed-to-expected (O/E) ratios were calculated, and a value index was derived to compare procedural strategies.

ResultsA total of 57,910 weighted hospitalizations were included (IABP 78%, pLVAD 22%). In-hospital mortality exceeded 30% across regions. Significant regional variation was observed, with the West demonstrating the highest costs and the Midwest the lowest (p<0.001). Mean hospital charges were higher for pLVAD compared with IABP ($403,731 vs $320,769). Both strategies achieved outcomes better than expected after risk adjustment (O/E 0.92); however, costs were higher than expected for both, with greater relative cost inflation observed for IABP (O/E 1.41) and higher absolute costs for pLVAD. In value-of-care analysis, IABP was associated with lower cost and comparable outcomes, while pLVAD demonstrated higher cost without proportional outcome improvement.

ConclusionSubstantial variation exists in the cost, outcomes, and value of pMCS strategies. While both IABP and pLVAD achieve favorable risk-adjusted outcomes, pLVAD is associated with higher costs without commensurate clinical benefit.

Related

  1. Stellate ganglion phototherapy for electrical storm during mechanical circulatory support in acute coronary syndrome: a case series
    European heart journal. Case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Mechanical circulatory support strategy in post-myocardial infarction ventricular septal defect repair.
    Caroline A Magro, Caroline Snyder, Katherine Phillips +4
    JTCVS openPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
  3. Mechanical circulatory support devices in heart failure: a narrative review of current evidence, clinical applications, complications, and future directions
    Ruirui Zhu, Fangyuan Zhang, Yudong Peng +1
    Frontiers in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Limiting collateral damage: Nosocomial infections in patients with temporary mechanical circulatory support.
    Ryan Dodge, Nicolas Kumar, Jonathan Tang +1
    JHLT openPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Update in short-term mechanical circulatory support: indications, devices and complications
    Jose María Moreno-Coca, Eva Moreno-Monterde, Antoni Manzano +2
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossrefPMC
BibTeX
@misc{greendyk2026costoutcome,
  title = {{Cost-Outcome Variation in Percutaneous Mechanical Circulatory Support: A National Value-of-Care Analysis}},
  author = {J. D. Greendyk and W. E. Allen and A. Hossain and Z. Trichas},
  howpublished = {medRxiv},
  year = {2026},
  month = aug,
  doi = {10.64898/2026.08.31.26361851},
  url = {https://www.medrxiv.org/content/10.64898/2026.08.31.26361851v1},
  note = {CC BY-NC},
}
RIS
TY  - UNPB
TI  - Cost-Outcome Variation in Percutaneous Mechanical Circulatory Support: A National Value-of-Care Analysis
AU  - J. D. Greendyk
AU  - W. E. Allen
AU  - A. Hossain
AU  - Z. Trichas
PY  - 2026
DA  - 2026/08/31
PB  - medRxiv
DO  - 10.64898/2026.08.31.26361851
UR  - https://www.medrxiv.org/content/10.64898/2026.08.31.26361851v1
AB  - BackgroundPercutaneous mechanical circulatory support (pMCS) is increasingly used in critically ill patients, yet its value in relation to cost and outcomes remains unclear. We evaluated national variation in utilization, outcomes, and cost, and introduced a value-of-care framework integrating risk-adjusted outcomes and expenditures.  MethodsWe performed a retrospective cohort study using the National Inpatient Sample to identify non-elective hospitalizations of critically ill patients undergoing intra-aortic balloon pump (IABP) or percutaneous left ventricular assist device (pLVAD) placement using ICD-10 codes. Multivariable logistic regression and generalized linear models were used to estimate expected outcomes and costs. Observed-to-expected (O/E) ratios were calculated, and a value index was derived to compare procedural strategies.  ResultsA total of 57,910 weighted hospitalizations were included (IABP 78%, pLVAD 22%). In-hospital mortality exceeded 30% across regions. Significant regional variation was observed, with the West demonstrating the highest costs and the Midwest the lowest (p<0.001). Mean hospital charges were higher for pLVAD compared with IABP ($403,731 vs $320,769). Both strategies achieved outcomes better than expected after risk adjustment (O/E 0.92); however, costs were higher than expected for both, with greater relative cost inflation observed for IABP (O/E 1.41) and higher absolute costs for pLVAD. In value-of-care analysis, IABP was associated with lower cost and comparable outcomes, while pLVAD demonstrated higher cost without proportional outcome improvement.  ConclusionSubstantial variation exists in the cost, outcomes, and value of pMCS strategies. While both IABP and pLVAD achieve favorable risk-adjusted outcomes, pLVAD is associated with higher costs without commensurate clinical benefit.
ER  -