Abstract
This narrative expert review provides a comprehensive overview of current biocompatibility testing standards and methodologies relevant to wound dressings, with the aim of supporting clinicians, purchasers, and other stakeholders in understanding their regulatory context, applicability, and limitations. Biological evaluation is essential to ensure that wound dressings are compatible with the biological environment and do not impede, and ideally support, the wound healing process. The article reviews the evolving landscape of laboratory‐based biocompatibility assessments, addressing key considerations including material degradation, cytotoxicity, systemic toxicity, irritation, and sensitisation. Specific attention is given to the application and impact of the ISO 10993 series and related international standards and guidance documents on testing requirements for wound dressings. In parallel, the review considers the principles of Replacement, Reduction, and Refinement (3Rs) in animal testing, alongside the increasing emphasis on generating more human‐relevant data. Emerging and advanced approaches, including in vitro tissue‐engineered models and in silico methods, are discussed in the context of their potential to reduce reliance on animal models while improving clinical predictivity. Overall, this review highlights current regulatory practice, known methodological limitations, and promising alternative strategies for advancing the biocompatibility evaluation of wound dressings. The review also considers emerging smart, nanocomposite, biopolymeric and bio‐fabricated dressing technologies, and the additional challenges that these advances create for biological evaluation.
Related
- Advances in Diagnostic Testing for Eosinophilic Esophagitis: Current Approaches, Limitations, and Emerging Technologies
- Evaluation of the physicomechanical properties and biocompatibility of low-viscosity denture base resins for 3D printing
- Endoscopic Endonasal Approaches to Anterior Cranial Base Meningiomas: Indications, Limitations, and Surgical Decision-Making.
- Postoperative opioid-induced respiratory depression monitoring in the context of supplemental oxygen: current limitations and emerging machine-learning approaches
- Animal Models for Preclinical Evaluation of Bioresorbable Scaffolds and Tissue-Engineered Constructs in Breast Reconstruction.
BibTeX
@article{cullen2026biocompatibility,
title = {{Biocompatibility Evaluation of Wound Dressing Materials and Constructs: Current Standards, Limitations and Emerging Approaches}},
author = {Breda Cullen and Emma Pedersen and Erik Nygren and Amit Gefen},
journal = {International wound journal},
year = {2026},
month = nov,
doi = {10.1111/iwj.71115},
url = {https://europepmc.org/article/PMC/PMC13789460},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Biocompatibility Evaluation of Wound Dressing Materials and Constructs: Current Standards, Limitations and Emerging Approaches
AU - Breda Cullen
AU - Emma Pedersen
AU - Erik Nygren
AU - Amit Gefen
PY - 2026
DA - 2026/11/01
JO - International wound journal
DO - 10.1111/iwj.71115
UR - https://europepmc.org/article/PMC/PMC13789460
AB - This narrative expert review provides a comprehensive overview of current biocompatibility testing standards and methodologies relevant to wound dressings, with the aim of supporting clinicians, purchasers, and other stakeholders in understanding their regulatory context, applicability, and limitations. Biological evaluation is essential to ensure that wound dressings are compatible with the biological environment and do not impede, and ideally support, the wound healing process. The article reviews the evolving landscape of laboratory‐based biocompatibility assessments, addressing key considerations including material degradation, cytotoxicity, systemic toxicity, irritation, and sensitisation. Specific attention is given to the application and impact of the ISO 10993 series and related international standards and guidance documents on testing requirements for wound dressings. In parallel, the review considers the principles of Replacement, Reduction, and Refinement (3Rs) in animal testing, alongside the increasing emphasis on generating more human‐relevant data. Emerging and advanced approaches, including in vitro tissue‐engineered models and in silico methods, are discussed in the context of their potential to reduce reliance on animal models while improving clinical predictivity. Overall, this review highlights current regulatory practice, known methodological limitations, and promising alternative strategies for advancing the biocompatibility evaluation of wound dressings. The review also considers emerging smart, nanocomposite, biopolymeric and bio‐fabricated dressing technologies, and the additional challenges that these advances create for biological evaluation.
SN - 1742-4801
SN - 1742-481X
ER -