Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 4 min ago
PreprintCC BYbioRxiv

Metric-driven Pre-acquisition Diagnostics for Automated Microscopy Ultraviolet Surface Excitation (MUSE)

Abstract

Background Automated microscopy enables large-scale tiled imaging but remains sensitive to variations in alignment, illumination, focus, and sample coverage that may only be detected after acquisition. We present an adaptive pre-acquisition quality-control framework for microscopy ultraviolet surface excitation (MUSE) that uses sparse scout imaging and tile-level metrics to guide acquisition and selective rescanning. Methods The framework quantifies brightness, dynamic range, focus, tissue fraction, and exposure error across the field of view. For example, in a representative 10 x 10 acquisition (100 tiles, 20-megapixel imagery), the mean p99 brightness was 0.525 (CV 10.4%), the mean dynamic range was 0.331, the median focus score was 0.0333, and the median tissue fraction was 0.943. Furthermore, applying a conservative exposure-error threshold (|error| > 0.25) identified 25% of tiles as rescan candidates. Results These results show that compact tile-level metrics can be converted into actionable quality gates, enabling early detection of local acquisition errors and targeted rescanning to improve mosaic consistency while minimizing unnecessary acquisition.

Related

  1. Automated reanalysis of genomic data for rare disease diagnostics at scale
    Matthew J. Welland, K. D. Ahlquist, Paul De Fazio +34
    Nature MedicinePeer-reviewedCC BY-NC-NDFull text23 citedGenetics & genomicsOpenAlex
  2. 3D-MAESTRO: A scalable, modular, portable pipeline for automated processing of large-scale volumetric brain microscopy data
    C. Laiton, N. Lusk, Y. Browning +27
    bioRxivPreprintCC BY-NCFull textNeurosciencebioRxiv
  3. Phosphate acquisition and metabolism in plants
    Yves Poirier, Aime Jaskolowski, Joaquín Clúa
    Current BiologyPeer-reviewedLicence not statedFull text167 citedPlant biologyHAL
  4. Tracking acquisition of cognitive maps in early- and late-onset blindness
    M. Bleau, Q. Dessain, L. Dricot +3
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  5. Beyond phosphate uptake: PT4/PT11 as key functional components linking phosphate acquisition, nutrient exchange, and arbuscule maintenance in arbuscular mycorrhizal symbiosis
    Xueying Yi, Ziming Ma
    Frontiers in plant sciencePeer-reviewedCC BYFull textPlant biologyEurope PMC
BibTeX
@misc{nunez2026metricdriven,
  title = {{Metric-driven Pre-acquisition Diagnostics for Automated Microscopy Ultraviolet Surface Excitation (MUSE)}},
  author = {M. Nunez and B. Davies},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.22.760904},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.22.760904v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Metric-driven Pre-acquisition Diagnostics for Automated Microscopy Ultraviolet Surface Excitation (MUSE)
AU  - M. Nunez
AU  - B. Davies
PY  - 2026
DA  - 2026/10/22
PB  - bioRxiv
DO  - 10.64898/2026.10.22.760904
UR  - https://www.biorxiv.org/content/10.64898/2026.10.22.760904v1
AB  - Background Automated microscopy enables large-scale tiled imaging but remains sensitive to variations in alignment, illumination, focus, and sample coverage that may only be detected after acquisition. We present an adaptive pre-acquisition quality-control framework for microscopy ultraviolet surface excitation (MUSE) that uses sparse scout imaging and tile-level metrics to guide acquisition and selective rescanning. Methods The framework quantifies brightness, dynamic range, focus, tissue fraction, and exposure error across the field of view. For example, in a representative 10 x 10 acquisition (100 tiles, 20-megapixel imagery), the mean p99 brightness was 0.525 (CV 10.4%), the mean dynamic range was 0.331, the median focus score was 0.0333, and the median tissue fraction was 0.943. Furthermore, applying a conservative exposure-error threshold (|error| > 0.25) identified 25% of tiles as rescan candidates. Results These results show that compact tile-level metrics can be converted into actionable quality gates, enabling early detection of local acquisition errors and targeted rescanning to improve mosaic consistency while minimizing unnecessary acquisition.
ER  -