Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 42 min ago
PreprintCC BY 4.0arXiv

Three-dimensional stochastic retinal models for synthetic eye-models

Abstract

Purpose: Current eye models often assume a fixed spherical retinal curvature of 12 mm, which does not reflect the anatomical variability observed in vivo. This study proposes an extension incorporating the stochastic relationship between axial length and three-dimensional (3D) retinal curvature, enabling more realistic 3D eye models. Methods: Axial length and 3D retinal curvature data from 94 subjects, split into five subsets for cross-validation, were used to construct two probabilistic models: a Single Gaussian Model (SGM) and two-component Multi Gaussian Mixture Model (MGMM). Both were converted into conditional forms to estimate retinal curvature for a specific axial length, and evaluated against measured data distributions. Results: All models produced radii of curvature comparable to measured data (median difference <0.2 mm). Non-conditionally, the MGMM described the distribution slightly better than SGM, with higher density overlap (>94% vs. >86%), but similar variance (worst f-test (p-value) 1.05 (0.71) vs. 1.05 (0.73)). Conditioned on axial length, both models performed similarly with overlap exceeding 93% and the worst f-test 1.02 (0.84). Given its simplicity and robustness, the conditional SGM was selected, achieving similar validation results: median difference (<0.10 mm), overlap (>92%), and a non-significant worst f-test (1.02 (0.85)). Conclusions: The conditional SGM enables accurate generation of anatomically realistic 3D retinal curvatures based on axial length, supporting improved stochastic eye modeling for visual optics and population-based simulations of healthy eyes. Translational relevance: Replacing the fixed 12 mm retina assumption with a population-based stochastic model improves anatomical accuracy of eye models used in optical design and treatment planning.

Related

  1. Emergent dynamical scaling in the inviscid limit of three-dimensional stochastic Navier–Stokes equation with thermal noise
    Liubov Gosteva, Marc Etienne Brachet, Léonie Canet
    Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering SciencesPeer-reviewedCC BY 4.0Full textCondensed matterFluid dynamicsHAL
  2. Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms
    Yuntao Wang
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
  3. Three-dimensional multipole states of the Bose-Einstein condensate of polar molecules in a shallow two-dimensional trapping potential
    S. Sanjay, S. Saravana Veni, Boris A. Malomed
    Physical Review ResearchPeer-reviewedCC BY 4.0Atomic, molecular & optical physicsCrossref
  4. An interdimensional funnel enhances topologically protected oscillations in high-dimensional stochastic systems
    Varsha Traynor, Jaime Agudo-Canalejo
    arXivPreprintarXiv licenceFull textBiological & medical physicsCondensed matterarXiv
  5. Open quantum battery in the background of a three-dimensional rotating black hole
    Xiaofang Liu, Zehua Tian, Jieci Wang
    Physics Letters BPeer-reviewedCC BY 4.0High-energy & particle physicsCrossref
BibTeX
@misc{dam2026threedimensional,
  title = {{Three-dimensional stochastic retinal models for synthetic eye-models}},
  author = {Nadine P. van Dam and Luc van Vught and Jos J. Rozema and Steven J. M. Habraken and Jan-Willem M. Beenakker},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.26544},
  eprint = {2610.26544},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.26544},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Three-dimensional stochastic retinal models for synthetic eye-models
AU  - Nadine P. van Dam
AU  - Luc van Vught
AU  - Jos J. Rozema
AU  - Steven J. M. Habraken
AU  - Jan-Willem M. Beenakker
PY  - 2026
DA  - 2026/10/19
PB  - arXiv
DO  - 10.48550/arxiv.2610.26544
UR  - https://arxiv.org/abs/2610.26544
AB  - Purpose: Current eye models often assume a fixed spherical retinal curvature of 12 mm, which does not reflect the anatomical variability observed in vivo. This study proposes an extension incorporating the stochastic relationship between axial length and three-dimensional (3D) retinal curvature, enabling more realistic 3D eye models. Methods: Axial length and 3D retinal curvature data from 94 subjects, split into five subsets for cross-validation, were used to construct two probabilistic models: a Single Gaussian Model (SGM) and two-component Multi Gaussian Mixture Model (MGMM). Both were converted into conditional forms to estimate retinal curvature for a specific axial length, and evaluated against measured data distributions. Results: All models produced radii of curvature comparable to measured data (median difference <0.2 mm). Non-conditionally, the MGMM described the distribution slightly better than SGM, with higher density overlap (>94% vs. >86%), but similar variance (worst f-test (p-value) 1.05 (0.71) vs. 1.05 (0.73)). Conditioned on axial length, both models performed similarly with overlap exceeding 93% and the worst f-test 1.02 (0.84). Given its simplicity and robustness, the conditional SGM was selected, achieving similar validation results: median difference (<0.10 mm), overlap (>92%), and a non-significant worst f-test (1.02 (0.85)). Conclusions: The conditional SGM enables accurate generation of anatomically realistic 3D retinal curvatures based on axial length, supporting improved stochastic eye modeling for visual optics and population-based simulations of healthy eyes. Translational relevance: Replacing the fixed 12 mm retina assumption with a population-based stochastic model improves anatomical accuracy of eye models used in optical design and treatment planning.
ER  -