METI-FS: a multi-evidence temporal integration framework for biomarker discovery in small-sample time-series transcriptomics.
8 affiliations
- 1Department of Pharmacology and Toxicology, Shenzhen Institute for Drug Control, Nanshan District, No. 28 Gaoxin Middle 2Nd Road, Shenzhen, 518000, Guangdong Province, China.
- 2Guangdong Provincial Engineering Technology Research Center for Quality Control of Innovative Cell and Gene Therapy Drugs, Shenzhen, 518000, Guangdong Province, China.
- 3Guangzhou National Laboratory, Guangzhou, 510005, Guangdong Province, China.
- 4Guangdong-Hong Kong-Macao Greater Bay Area Center for Drug Evaluation and Inspection of National Medical Products Administration, Shenzhen, 518000, Guangdong Province, China.
- 5Department of Pharmacology and Toxicology, Shenzhen Institute for Drug Control, Nanshan District, No. 28 Gaoxin Middle 2Nd Road, Shenzhen, 518000, Guangdong Province, China. [email protected].
- 6Guangdong Provincial Engineering Technology Research Center for Quality Control of Innovative Cell and Gene Therapy Drugs, Shenzhen, 518000, Guangdong Province, China. [email protected].
- 7Department of Pharmacology and Toxicology, Shenzhen Institute for Drug Control, Nanshan District, No. 28 Gaoxin Middle 2Nd Road, Shenzhen, 518000, Guangdong Province, China. [email protected].
- 8Guangdong Provincial Engineering Technology Research Center for Quality Control of Innovative Cell and Gene Therapy Drugs, Shenzhen, 518000, Guangdong Province, China. [email protected].
Abstract
Background
Selecting a small set of experimentally verifiable candidate biomarkers from small-sample, time-series RNA-seq data (n < 50, p > 10,000) remains a critical bottleneck for downstream functional studies. Current approaches suffer from three unresolved limitations: differential expression-based pre-filtering lacks temporal awareness, machine learning-based feature selection lacks automatic sparsity control, and individual analytical steps are not integrated into a coherent end-to-end workflow.Results
We developed METI-FS (Multi-Evidence Temporal Integration for Feature Selection), a multi-evidence integration framework whose principal contribution is temporally aware upstream compression: through the intersection of maSigPro temporal regression, WGCNA co-expression network analysis, and DESeq2-based minimum effect size testing, METI-FS systematically reduces the feature space from p > 10,000 to a high-quality candidate pool containing several hundred to several thousand genes, thereby improving the selection stability of a broad range of downstream machine learning methods. A data-driven gap-union threshold automatically determines the final feature set size with minimal user-specified parameters. Across 210 simulation scenarios encompassing six co-expression architectures, METI-FS achieved a relaxed precision (precision_any) of 0.904, indicating that over 90% of the selected genes carried genuine temporal signal (strict precision: 0.408 ± 0.308; F1: 0.296 ± 0.178). Ablation analysis with full paired comparisons identified maSigPro temporal filtering as the most critical upstream component (ΔF1 = -0.206 ± 0.169). On four cross-domain GEO datasets spanning immune activation, anti-tumor drug response, viral infection, and cartilage inflammation, METI-FS achieved compression ratios ranging from 602:1 to 2722:1 without any parameter adjustment. Across all four datasets, the effect size filter (which tests whether each gene's log₂ fold change statistically exceeds a minimum threshold) removed 14-77% of genes that passed temporal and co-expression filters, demonstrating that statistical significance and biological significance require independent assessment. A two-layer benchmarking framework demonstrated that maSigPro-based upstream filtering improved downstream Boruta selection stability by 65% on average across datasets (mean pairwise Jaccard index: 0.288 to 0.475). Cross-validation against published literature across all four datasets confirmed that 75% (41 of 55) of the candidate genes had independent functional evidence, demonstrating that METI-FS, without any biological prior knowledge, independently converges on genes with established functional roles.Conclusions
METI-FS provides a largely automated end-to-end framework for biomarker discovery in small-sample, time-series transcriptomics. Its core contribution is temporally aware upstream compression that systematically enhances the selection stability of a broad range of downstream methods, coupled with data-driven sparsity control that eliminates manual parameter tuning. The R implementation and all analysis scripts are publicly available at GitHub.
Related
- SemanticST: A Scalable Multi‐Contextual Graph Learning Framework for Uncovering Spatial Niches and Robust Multi‐Sample Integration in Spatial Transcriptomics
- Post-Treatment Molecular Biomarker Reassessment in Advanced Endometrial Cancer: An Evidence-Aware Framework for Precision Therapy
- AI-guided design and biomaterial integration for next-generation extracellular vesicle therapeutics: an evidence-weighted translational framework.
- Structural diversity of human urinary N-glycans revealed by reversed-phase LC/MS/MS toward a resource for biomarker discovery
- Flow Cytometry and AI-Driven Biomarker Discovery in Acute Kidney Injury: From Mechanistic Insights to Translation Applications in Clinical and Austere Environments
BibTeX
@article{zhang2026metifs,
title = {{METI-FS: a multi-evidence temporal integration framework for biomarker discovery in small-sample time-series transcriptomics.}},
author = {Zhen Zhang and Tengjiao Ma and Yangmei Xu and Sisi Deng and Chunqi Xu and Jiawei Li and Ning Chen and Meirong Qin and Ping Wang},
journal = {BMC bioinformatics},
year = {2026},
month = aug,
doi = {10.1186/s12859-026-06588-9},
url = {https://europepmc.org/article/MED/43052724},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - METI-FS: a multi-evidence temporal integration framework for biomarker discovery in small-sample time-series transcriptomics.
AU - Zhen Zhang
AU - Tengjiao Ma
AU - Yangmei Xu
AU - Sisi Deng
AU - Chunqi Xu
AU - Jiawei Li
AU - Ning Chen
AU - Meirong Qin
AU - Ping Wang
PY - 2026
DA - 2026/08/25
JO - BMC bioinformatics
DO - 10.1186/s12859-026-06588-9
UR - https://europepmc.org/article/MED/43052724
AB - Background Selecting a small set of experimentally verifiable candidate biomarkers from small-sample, time-series RNA-seq data (n < 50, p > 10,000) remains a critical bottleneck for downstream functional studies. Current approaches suffer from three unresolved limitations: differential expression-based pre-filtering lacks temporal awareness, machine learning-based feature selection lacks automatic sparsity control, and individual analytical steps are not integrated into a coherent end-to-end workflow.Results We developed METI-FS (Multi-Evidence Temporal Integration for Feature Selection), a multi-evidence integration framework whose principal contribution is temporally aware upstream compression: through the intersection of maSigPro temporal regression, WGCNA co-expression network analysis, and DESeq2-based minimum effect size testing, METI-FS systematically reduces the feature space from p > 10,000 to a high-quality candidate pool containing several hundred to several thousand genes, thereby improving the selection stability of a broad range of downstream machine learning methods. A data-driven gap-union threshold automatically determines the final feature set size with minimal user-specified parameters. Across 210 simulation scenarios encompassing six co-expression architectures, METI-FS achieved a relaxed precision (precision_any) of 0.904, indicating that over 90% of the selected genes carried genuine temporal signal (strict precision: 0.408 ± 0.308; F1: 0.296 ± 0.178). Ablation analysis with full paired comparisons identified maSigPro temporal filtering as the most critical upstream component (ΔF1 = -0.206 ± 0.169). On four cross-domain GEO datasets spanning immune activation, anti-tumor drug response, viral infection, and cartilage inflammation, METI-FS achieved compression ratios ranging from 602:1 to 2722:1 without any parameter adjustment. Across all four datasets, the effect size filter (which tests whether each gene's log₂ fold change statistically exceeds a minimum threshold) removed 14-77% of genes that passed temporal and co-expression filters, demonstrating that statistical significance and biological significance require independent assessment. A two-layer benchmarking framework demonstrated that maSigPro-based upstream filtering improved downstream Boruta selection stability by 65% on average across datasets (mean pairwise Jaccard index: 0.288 to 0.475). Cross-validation against published literature across all four datasets confirmed that 75% (41 of 55) of the candidate genes had independent functional evidence, demonstrating that METI-FS, without any biological prior knowledge, independently converges on genes with established functional roles.Conclusions METI-FS provides a largely automated end-to-end framework for biomarker discovery in small-sample, time-series transcriptomics. Its core contribution is temporally aware upstream compression that systematically enhances the selection stability of a broad range of downstream methods, coupled with data-driven sparsity control that eliminates manual parameter tuning. The R implementation and all analysis scripts are publicly available at GitHub.
SN - 1471-2105
ER -