Association Between Myocardial BOLD Reactivity and Peripheral Microvascular Function Assessed by Flow‐Mediated Skin Fluorescence
6 affiliations
- 12nd Department of Radiology Medical University of Gdańsk Gdańsk Poland
- 2Department of Radiology University Medical Center Groningen Groningen the Netherlands
- 3Department of Neurology Medical University of Innsbruck Innsbruck Austria
- 4Department of Cardiac Diagnostics Medical University of Gdańsk Gdańsk Poland
- 5Interdisciplinary Pomeranian Centre for Digital Medicine Medical University of Gdańsk Gdańsk Poland
- 6Department of Nuclear Medicine and Molecular Imaging University Medical Center Groningen Groningen the Netherlands
Abstract
Cardiac blood oxygen level–dependent (BOLD) MRI during breath‐hold provides a contrast‐free myocardial‐specific readout of vasoreactivity. We tested whether myocardial BOLD reactivity covaries with peripheral microvascular function measured by flow‐mediated skin fluorescence (FMSF), thereby assessing concordance between two physiologically distinct vascular beds. Twenty‐eight participants underwent a mid‐diastolic cardiac BOLD MRI at 1.5 T during end‐expiratory breath‐hold, alongside forearm FMSF during transient brachial artery occlusion. Participants were classified as having FMSF‐normal reactivity (NR) or FMSF‐abnormal reactivity (AR) based on predefined FMSF criteria (i.e., one or more of the following: reactive hyperemia response [RHR] < 30% or hypoxia sensitivity [HS] < 25). Heartbeat‐to‐heartbeat myocardial T2 and T2* slopes (ms/hb) and absolute changes (ΔT2, ΔT2*) were compared between cohorts and correlated with FMSF parameters. Compared with AR, the NR showed greater T2 slope (0.1 ± 0.2 vs. −0.2 ± 0.3 ms/hb; p = 0.002), T2* slope (0.1 ± 0.2 vs. 0.0 ± 0.1 ms/hb; p = 0.016), ΔT2 (1.3 ± 2.2 vs. −1.9 ± 2.9 ms; p = 0.003) and ΔT2* (2.4 ± 2.8 vs. −0.1 ± 2.1 ms; p = 0.013). After Benjamini–Hochberg false discovery rate (FDR) correction across 44 correlations, IR index correlated with T2 slope (r = 0.58, q = 0.050), IR max correlated with T2 slope (r = 0.57, q = 0.050), and HS correlated with ΔT2* (r = 0.53, q = 0.050). Interreader reproducibility was good for myocardial BOLD‐derived slopes and ΔT2* (ICC = 0.80–0.86) and moderate for ΔT2 (ICC = 0.66). Within this long‐COVID cohort, myocardial BOLD reactivity covaried with peripheral microvascular reactivity at the group level. Cardiac BOLD MRI may serve as a myocardial‐specific probe of microvascular function within a broader systemic vascular phenotype.
Related
- Mental Stress-Induced Peripheral Microvascular Dysfunction and Cardiovascular Events after a Premature Myocardial Infarction: A Prospective Cohort Study
- Dynamic Macro-Microvascular Coupling During Cerebrovascular Reactivity Revealed by Simultaneous TCD and DCS
- Differential Contributions of CO2 and Blood Pressure to Cerebral Macro- and Microvascular Reactivity in healthy adults
- SGLT2i protects against myocardial I/R-induced coronary microvascular injury by inhibiting glycocalyx degradation
- Sotatercept-related peripheral microvascular alterations in systemic sclerosis–associated pulmonary arterial hypertension: insights from nailfold capillaroscopy
BibTeX
@article{castelein2026association,
title = {{Association Between Myocardial BOLD Reactivity and Peripheral Microvascular Function Assessed by Flow‐Mediated Skin Fluorescence}},
author = {Johannes Castelein and Agnieszka Sabisz and Anna Glińska and Marta Żarczyńska‐Buchowiecka and Marzena Romanowska‐Kocejko and Marlena Rygusik and Marcin Hellmann and Ronald J. H. Borra and Karolina Dorniak},
journal = {Nmr in Biomedicine},
year = {2026},
month = nov,
doi = {10.1002/nbm.70446},
url = {https://doi.org/10.1002/nbm.70446},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Association Between Myocardial BOLD Reactivity and Peripheral Microvascular Function Assessed by Flow‐Mediated Skin Fluorescence
AU - Johannes Castelein
AU - Agnieszka Sabisz
AU - Anna Glińska
AU - Marta Żarczyńska‐Buchowiecka
AU - Marzena Romanowska‐Kocejko
AU - Marlena Rygusik
AU - Marcin Hellmann
AU - Ronald J. H. Borra
AU - Karolina Dorniak
PY - 2026
DA - 2026/11/23
JO - Nmr in Biomedicine
DO - 10.1002/nbm.70446
UR - https://doi.org/10.1002/nbm.70446
AB - Cardiac blood oxygen level–dependent (BOLD) MRI during breath‐hold provides a contrast‐free myocardial‐specific readout of vasoreactivity. We tested whether myocardial BOLD reactivity covaries with peripheral microvascular function measured by flow‐mediated skin fluorescence (FMSF), thereby assessing concordance between two physiologically distinct vascular beds. Twenty‐eight participants underwent a mid‐diastolic cardiac BOLD MRI at 1.5 T during end‐expiratory breath‐hold, alongside forearm FMSF during transient brachial artery occlusion. Participants were classified as having FMSF‐normal reactivity (NR) or FMSF‐abnormal reactivity (AR) based on predefined FMSF criteria (i.e., one or more of the following: reactive hyperemia response [RHR] < 30% or hypoxia sensitivity [HS] < 25). Heartbeat‐to‐heartbeat myocardial T2 and T2* slopes (ms/hb) and absolute changes (ΔT2, ΔT2*) were compared between cohorts and correlated with FMSF parameters. Compared with AR, the NR showed greater T2 slope (0.1 ± 0.2 vs. −0.2 ± 0.3 ms/hb; p = 0.002), T2* slope (0.1 ± 0.2 vs. 0.0 ± 0.1 ms/hb; p = 0.016), ΔT2 (1.3 ± 2.2 vs. −1.9 ± 2.9 ms; p = 0.003) and ΔT2* (2.4 ± 2.8 vs. −0.1 ± 2.1 ms; p = 0.013). After Benjamini–Hochberg false discovery rate (FDR) correction across 44 correlations, IR index correlated with T2 slope (r = 0.58, q = 0.050), IR max correlated with T2 slope (r = 0.57, q = 0.050), and HS correlated with ΔT2* (r = 0.53, q = 0.050). Interreader reproducibility was good for myocardial BOLD‐derived slopes and ΔT2* (ICC = 0.80–0.86) and moderate for ΔT2 (ICC = 0.66). Within this long‐COVID cohort, myocardial BOLD reactivity covaried with peripheral microvascular reactivity at the group level. Cardiac BOLD MRI may serve as a myocardial‐specific probe of microvascular function within a broader systemic vascular phenotype.
SN - 0952-3480
SN - 1099-1492
ER -